background image

 

24 

WHAT TO EXPECT IN THE FIRST FEW WEEKS  

 

During the first 1-6 weeks after the installation of the ecoTAC™ conditioner, a de-scaling 

effect whereby existing hard water scale previously built-up in the plumbing system is 

released, will often occur.  Over time, this will enhance performance of water heating 

equipment and restore flow performance of plumbing fixtures.  However, it may be 

necessary to clean out your faucet aerators and showerhead periodically during this period 

to remove pieces of scale that have dislodged from your pipes.  This effect will stop once the 

pipes have been de-scaled. 

 

After installation of EcoTAC™, low or phosphate-free cleaning products (for clothes and 

dishwashing) are recommended to achieve optimum results. Modern surfactant or 

detergent based, liquid soaps are preferred over old-fashioned caustic solid soaps. 

 

Water heaters 

 

Existing mineral accumulations in your water heater may also de-scale after the installation 

of ecoTAC™.  We recommend that you clean out this material by opening the bottom drain 

valve on the hot water heater 30 to 60 days after installation of ecoTAC™.  Be sure to turn off 

the electricity to your water heater before draining your tank. Follow the manufacturer’s 

instructions for draining and flushing the tank.  The good news is that a clean water heater 

uses much less electricity or gas to keep the water hot! 

 

Using your dishwasher after installing ecoTAC™ 

 

To accelerate de-scaling in your dishwasher, you may wish to put a cup of white vinegar in 

the upper basket during the washing cycle for the first few weeks. You can also use citric 

acid or a commercial product like CLR or Lime Away instead of the white vinegar. This will 

help dissolve the existing scale in the washer arms and inside surface of the dishwasher. 

You may need to do this until all of the scale in the plumbing is dissolved. If you are using 

harsh dishwashing detergents that have low ph, high chlorine, and phosphates, some of the 

nano-crystals formed by the ecoTAC™ system may break down and cause spotting on the 

dishes. We recommend that you reduce your soap usage as much as 50%, and that you use 

eco-friendly phosphate-free dishwashing detergents.  Using an anti-spotting agent such as 

Jet-Dry® may also be useful. 

 

 

 

Summary of Contents for EP-1000-ULT

Page 1: ...TION GUIDE ecoPLUS EP 1000 ULT PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION FAILURE TO FOLLOW THESE INSTRUCTIONS MAY AFFECT THE PERFORMANCE OF YOUR SYSTEM VOID YOUR WARRANTY AND RE...

Page 2: ...amaging effects of these contaminants Our ecoTAC hard water conditioners use a salt free water treatment technology called Template Assisted Crystalization or TAC for short to prevent hard water scale...

Page 3: ...p 8 Connect the Inlet Assembly to the Housing Cap 15 Step 9 Connect the Bypass to the Inlet Assembly 16 Step 10 Connect the ecoPLUS Tank to the Inlet Assembly 16 Step 11 Connect Bridge Assembly to the...

Page 4: ...avy components without assistance if you are not physically capable of safely carrying out the procedure If the water treatment system is to be left unattended for an extended period of time vacation...

Page 5: ...SYSTEM DAMAGE INCLUDING WATER LEAKS AND CORRESPONDING PROPERTY DAMAGE AND MAY VOID YOUR WARRANTY It is very important to note that the presence of elevated levels of chlorine iron manganese hydrogen...

Page 6: ...hstand pressures exceeding 90 PSI if your water pressure is greater than 70 PSI we recommend that you have a certified plumber install a pressure reducing valve ahead of the ecoPLUS system The system...

Page 7: ...INIMIZE ANY PROBLEMS WITH COPPER AVOID APPLYING EXCESS FLUX ON THE INNER SURFACES OF THE PIPE AND USE A LOW CORROSIVITY WATER SOLUBLE FLUX LISTED UNDER THE ASTM B813 STANDARD FOR HOMES WITH SIGNIFICAN...

Page 8: ...8 Step 1 Pre Installation Inspection...

Page 9: ...el Connectors 1 Quick Connect to 1 NPT 8 Outlet Assembly 9 Inlet Assembly 10 Spanner Wrench 11 Small Parts Bag 8 Lag Bolts and 8 Washers 12 ecoTAC Media Tank and Valve Head 13 Bridge Assembly 14 UV Co...

Page 10: ...n space required for this model is 42 Wide x 66 High x 21 5 Deep In most cases the system should be installed after the branch line s to exterior irrigation unless you want your exterior faucets to de...

Page 11: ...tach the cartridge filter housing cap and mounting bracket to your wall using the remaining four 4 lag bolts and washers as shown below The top of the mounting bracket should be mounted EXACTLY 52 3 4...

Page 12: ...nsuring that it is securely screwed into the wall studs When the cartridge filter housing is full of water it is heavy so it is important to ensure that the mounting will be strong enough to support t...

Page 13: ...sump containing the filter cartridge onto the cartridge filter housing cap Hand tighten only do not use the spanner wrench Do not over tighten Excessive force is not required to obtain a good seal Ste...

Page 14: ...he treatment tank This is completely normal and is necessary to allow the required freeboard to permit the media bed to completely fluidize during operation When water begins to flow into the bottom o...

Page 15: ...Cap Refer to John Guest Quick Connect Style Fittings above First ensure the John Guest fitting is unlocked Then push the elbow end of the inlet assembly on to the black stem adapter as far as it will...

Page 16: ...hed to the rest of the tank If your tank appears to be crooked the base has likely been knocked out of alignment during shipping This can be correct by picking the tank up and tapping it on a hard sur...

Page 17: ...17 go to next page...

Page 18: ...S treatment tank The black base of the media tank is not permanently attached to the rest of the tank If your tank appears to be crooked the base has likely been knocked out of alignment during shippi...

Page 19: ...s not required to obtain a good seal The other end to the inlet bottom port on the UV disinfection chamber in the same manner The flexible connector can be bent to reach the UV chamber which should be...

Page 20: ...s much water out of the plumbing system as possible Following completion of the entire installation restore the water flow by turning on the household main water valve and allow all air to be purged f...

Page 21: ...r incoming water line It is designed to be bent a many times but not repeatedly over and over Doing so may reduce the structural integrity of the fitting Alternatively you can make the plumbing connec...

Page 22: ...sulted from the installation Once the water is running clear and free of air close the water tap INSPECT ALL PLUMBING CONNECTIONS AND THE INTERFACE BETWEEN THE MEDIA TANK AND ITS VALVE HEAD FOR LEAKS...

Page 23: ...t is normal for the water to be discolored at this stage as carbon fines are purged from the system Gradually increase the flow rate a little more and run the water until it is completely clear If you...

Page 24: ...bottom drain valve on the hot water heater 30 to 60 days after installation of ecoTAC Be sure to turn off the electricity to your water heater before draining your tank Follow the manufacturer s inst...

Page 25: ...sily wiped down because they can no longer adhere to the sides of the shower TROUBLESHOOTING Problem Solution Reduced water pressure and or flow rate after initial installation Limit high flow rate de...

Page 26: ...T SEVERAL FAUCETS Cleaning The outside of your system including cartridge filter housing and media tank can be washed with a mild soap and water if desired Do NOT use strong cleaners as they may cause...

Page 27: ...ot be stopped Put the O ring in a safe place where it will not get dirty or otherwise contaminated Replacement O Ring Pentek Buna N Big Blue O Ring 151122 4 Take out the used filter cartridge and disc...

Page 28: ...or our ecoTAC hard water conditioner this may need to be done every few months If you have soft water or you have treatment for your hard water problem sleeve cleaning is generally only required once...

Page 29: ...lytic Activated Carbons Calgon Carbon Corporation Moon Township PA USA Made in USA NSF ANSI Standard 61 KDF 55 Process Media KDF Fluid Treatment Inc Three Rivers MI USA Made in USA NSF ANSI Standard 4...

Page 30: ...mprehensive warranty program including Limited Lifetime Warranty on major components Major components including the cartridge filter housing media tank s riser tube s upper media screen s and tank val...

Page 31: ...This warranty applies only in Canada and the United States of America In the event that a part is deemed defective the user must immediately inform HomePlus Products Inc who will furnish a replacemen...

Page 32: ...xceed the actual purchase price paid by the authorized distributor or consumer for the product In no event shall HomePlus Products Inc be liable to the distributor or any other person or entity for sp...

Reviews: