background image

1

Displaying Schedule

Press the 

NEXT

 key to display 

the Day and Night schedule for 
each day of the week.

Schedule

CANCEL

NEXT

SYSTEM

Day

Press the 

CANCEL

 key to return 

to normal operation.

AM

Press and hold the 

MENU

 key to 

display the schedule.

Mo

1

Low Battery Indication

When battery voltage drops from 
3.3V down to 2.5V, the LCD will 
alternately display “Lo” in place of 
the Inside temperature, and the 
LCD backlighting is turned off to 
extend battery life. The wireless 
communication continues to 
operate but the range is reduced.

Batteries should be replaced with 
AA alkaline or lithium batteries.

Inside

Mo

Schedule

AM

Set To

MENU

MODE

NEXT

ENTER

SYSTEM

HEAT

Day

Inside

Mo

Schedule

AM

Set To

MENU

MODE

NEXT

ENTER

SYSTEM

HEAT

Day

Slide the battery cover off and 
install two AA lithium or alkaline 
batteries.  Install the batteries 
with the positive terminals to 
the right as shown.  Replace 
the battery cover.

Installing Batteries

1

Calibrating the Temperature Sensor

Press the 

 key three times 

until the temperature is displayed. 

MENU

Inside

MENU

MODE

NEXT

ENTER

SYSTEM

Press the 

or 

 key to 

adjust the temperature to the 
temperature that the user feels is 
correct.

UP 

DOWN

Press the 

key to save 

and return to normal operation.

ENTER 

4

Summary of Contents for T200WLD

Page 1: ...low to the space The thermostat maintains the temperature using the system mode and setpoint temperature set by the user and the space temperature Automatically controls airflow based on selected syst...

Page 2: ...Off Heat or Cool The System Mode selected by the user needs to correspond to the current system mode of the HVAC equipment OFF MODE In Off Mode the thermostat sets the airflow to the Off Airflow Leve...

Page 3: ...d NEXT Schedule PM MENU MODE NEXT ENTER SYSTEM Night All days are displayed The number in the upper right corner shows the day of the week being selected or deselected 1 is Monday 2 is Tuesday etc Pre...

Page 4: ...ange is reduced Batteries should be replaced with AA alkaline or lithium batteries Inside Mo Schedule AM Set To MENU MODE NEXT ENTER SYSTEM HEAT Day Inside Mo Schedule AM Set To MENU MODE NEXT ENTER S...

Page 5: ...Range Range Range Range 1 to 8 1 to 8 1 to 5 F o 60 to 90 F o 55 to 80 F o 0 to 100 0 to 100 0 8 F 1 16 F 5 to 30 minutes 0 On with key Default 1 1 1 F o 80 F o 65 F o 50 50 0 8 F 10 minutes On with k...

Page 6: ...thermostat makes an adjustment to the airflow If the deadband is set for 1 degree the room temperature must be more than 1 degree warmer or cooler than the setpoint temperature before the damper posit...

Page 7: ...ss 1 The dampers are powered by 24VAC and require only 2 8VA when operating and only 1VA when holding A 40VA transformer can power up to 10 dampers The damper or dampers controlling airflow to the spa...

Page 8: ...ise position the damper will completely close In the fully clockwise position the damper will close to about 50 closed allowing some air to pass even when the user sets the damper to fully closed Repl...

Reviews: