6
Touch the
keys to
change the minimum off time
(minutes) before restarting the
compressor.
Touch
to display the
next option, or
to save
the option and return to normal
thermostat operation.
UP/DOWN
NEXT
ENTER
Option
NEXT
ENTER
Option
NEXT
ENTER
Touch the
keys to
change the minimum run time
(minutes) before turning a
system off.
Touch
to display the
next option, or
to save
the option and return to normal
thermostat operation.
UP/DOWN
NEXT
ENTER
Option
NEXT
ENTER
Touch the
keys to
change the minimum off time
(minutes) before restarting a
gas furnace or electric strip
heater.
Touch
to display the
next option, or
to save
the option and return to normal
thermostat operation.
UP/DOWN
NEXT
ENTER
Touch the
keys to
select 0, 1, 2.
Touch
to display the
next option, or
to save
the option and return to normal
thermostat operation, or touch
the hidden
key to return
to the previous option.
UP/DOWN
NEXT
ENTER
BACK
Option
NEXT
ENTER
0
1
2
o
Turns cooling On 1 above setpoint and Off at Setpoint.
o
o
Turns cooling On 1 above setpoint, Off .5 below Setpoint.
Turns cooling On 1 above setpoint, Off 1 below Setpoint.
o
o
Turns heating On 1 below setpoint and Off at Setpoint.
o
o
o
Turns heating On 1 below setpoint, Off .5 above Setpoint.
o
o
Turns heating On 1 below setpoint, Off 1 above Setpoint
.
Touch the
key to select ON
to turn on smart recovery or
touch the
key to select
OF to turn smart recovery off.
Touch
to display the
next option, or
to save
the option and return to normal
thermostat operation.
UP
DOWN
NEXT
ENTER
Smart recovery initiates a heating or cooling call so that the space is
at temperature when the setback period ends.
Option
NEXT
ENTER
Touch the
keys to
select the heating temperature
when the space is vacant.
Touch
to display the
next option, or
to save
the option and return to normal
thermostat operation, or touch
the hidden
key to return
to the previous option.
UP/DOWN
NEXT
ENTER
BACK
Option
NEXT
ENTER
Touch the
keys to
select the cooling temperature
when the space is vacant.
Touch
to display the
next option, or
to save
the option and return to normal
thermostat operation, or touch
the hidden
key to return
to the previous option.
UP/DOWN
NEXT
ENTER
BACK
Option
NEXT
ENTER
Cool
Vacant
Vacant
Touch the
keys to
change the downstairs (Inside)
temperature to the temperature
that the user feels is correct.
Touch
to display the
next option, or
to save
the option and return to normal
thermostat operation, or touch
the hidden
key to return
to the previous option.
UP/DOWN
NEXT
ENTER
BACK
Inside
Option
NEXT
ENTER
Heat
Touch the
UP/DOWN
keys to
change the upstairs (Inside2)
temperature to the temperature
that the user feels is correct.
Touch
NEXT
to display the
next option, or
ENTER
to save
the option and return to normal
thermostat operation, or touch
the hidden
BACK
key to return
to the previous option.
Inside2
Option
NEXT
ENTER
Touch the
keys to
set the time in minutes to
update the upstairs and
downstairs airflow.
Touch
to display the
next option, or
to save
the option and return to normal
thermostat operation, or touch
the hidden
key to return
to the previous option.
UP/DOWN
NEXT
ENTER
BACK
Option
NEXT
ENTER
This is the frequency, in minutes, that the damper position is updated.
04 Compressor Minimum Off Time
Factory Default: 2 Minutes. Range: 0 to 9 Minutes
05 Heating Minimum Off Time
Factory Default: 0 Minutes. Range: 0 to 9 Minutes
06 Minimum Run Time
Factory Default: 2 Minutes. Range: 0 to 9 Minutes
10 Vacant Cooling Setpoint
o
o
Range: 74 F to 95 F
o
Factory Default: 80 F.
09 Vacant Heating Setpoint
o
o
Range: 44 F to 75 F
o
Factory Default: 65 F.
07 Setting On-Off Temp Differential
Factory Default: #1. Range: 0, 1 or 2.
08 Smart Recovery
Factory Default: Off. Range: On or Off.
11 Calibrate Downstairs Temperature Sensor
Factory Default: None.
o
Range - +/-5
12 Calibrate Upstairs Temperature Sensor
Factory Default: None.
o
Range - +/-5
13 Airflow Update Time
Factory Default: 2 Minutes. Range: 1 to 20 Minutes.