background image

7

Option

NEXT

ENTER

Night

Touch the 

key to turn the 

low level backlight ON or touch 
the 

 key to turn OFF.  

Touch 

 to display the 

next option, or

 to save 

the option and return to normal 
thermostat operation, or touch 
the hidden 

 key to return 

to the previous option.

UP 

 

DOWN

NEXT

 ENTER

BACK

Touch the 

 key to select ON 

to enable manual airflow 
control or touch the 

 key 

to select Off so that manual 
airflow control is not an option. 

Touch 

 to display the next 

option, or

 to save the 

option and return to normal 
thermostat operation, or touch 
the hidden 

 key to return 

to the previous option.

UP

DOWN

NEXT

 ENTER

BACK

This option enables the consumer to override automatic airflow control 
for 3 hours. If off, the user will not be able to override automatic airflow 
control.

Option

NEXT

ENTER

Touch the 

 key to select ON 

for airflow control or touch the 

 key to select OFF to 

disable airflow control. 

Touch 

 to display the 

next option, or

 to save 

the option and return to normal 
thermostat operation, or touch 
the hidden 

 key to return 

to the previous option.

UP

DOWN

NEXT

 ENTER

BACK

Upstairs

Downstairs

Airflow %

Option

NEXT

ENTER

This option turns the automatic airflow control on or off. If on, the 
thermostat will automatically adjust the airflow. If off, airflow is disabled.

Touch the 

 keys to 

select the maximum allowable 
upstairs airflow in heating. 

Touch 

 to display the next 

option, or

 to save the 

option and return to normal 
thermostat operation, or touch 
the hidden 

 key to return 

to the previous option.

UP/DOWN

NEXT

 ENTER

BACK

Upstairs

Airflow %

Option

NEXT

ENTER

Heat

For options 17 - 20, use the installer test o

imum allowable airflow.

n pages 7-8 to 

determine the max

Touch the 

 keys to 

select the maximum allowable 
upstairs airflow in cooling. 

Touch 

 to display the 

next option, or

 to save 

the option and return to normal 
thermostat operation, or touch 
the hidden 

 key to return 

to the previous option.

UP/DOWN

NEXT

 ENTER

BACK

Upstairs

Airflow %

Option

NEXT

ENTER

Cool

Touch the 

 keys to 

select the maximum allowable 
downstairs airflow in heating.

Touch 

 to display the 

next option, or

 to save 

the option and return to normal 
thermostat operation, or touch 
the hidden 

 key to return 

to the previous option.

UP/DOWN

NEXT

 ENTER

BACK

Downstairs

Airflow %

Option

NEXT

ENTER

Heat

Touch the 

 keys to 

select the maximum allowable 
downstairs airflow in cooling.

Touch 

 to display the 

next option, or

 to save 

the option and return to normal 
thermostat operation, or touch 
the hidden 

 key to return 

to the previous option.

UP/DOWN

NEXT

 ENTER

BACK

Downstairs

Airflow %

Option

NEXT

ENTER

Cool

Touch the 

 keys to 

select the maximum allowable 
temperature difference between 
the upstairs and downstairs. 

Touch 

 to display the next 

option, or

 to save the 

option and return to normal 
thermostat operation, or touch 
the hidden 

 key to return 

to the previous option.

UP/DOWN

NEXT

 ENTER

BACK

Upstairs

Downstairs

Airflow %

Option

NEXT

ENTER

Touch 

NEXT

 or 

 to 

return to normal thermostat 
operation. Touch the hidden 

BACK

 key to return to previous 

option.

To restore factory settings, 
touch 

ENTER

, then touch the 

UP

 key.

ENTER

Option

NEXT

ENTER

This the maximum allowable temperature difference between the 
upstairs and downstairs temperatures. When the temperature 
difference is equal to or greater than the allowed differential, the airflow 
is adjusted.

The LCD has a low level backlight that can be used as a night light.

Downstairs

Downstairs

Upstairs

Upstairs

14  Night Level LCD Backlight

Factory Default: On. Range: On or Off.

15  Airflow Control, On or Off

Factory Default: On. Range: On or Off.

16  Enable Selecting Manual Airflow Control

Factory Default: Off. Range: On or Off.

17  Maximum Upstairs Airflow in Heating

Factory Default: 150%.   Range: 100% to 160%.

18  Maximum Upstairs Airflow in Cooling

Factory Default: 140%.   Range: 100% to 160%.

19  Maximum Downstairs Airflow in Heating

Factory Default: 150%.   Range: 100% to 160%.

20  Maximum Downstairs Airflow in Cooling

Factory Default: 140%.   Range: 100% to 160%.

21  Maximum Temperature Differential

o

Factory Default: 2 F. 

Range: 0  to 10 F

22  Factory Restore

WARNING! Factory Restore 
                   resets ALL settings.

Summary of Contents for Comfort 365 C365T11

Page 1: ...ing only Cooling only Automatic Heating or Cooling Maximum upstairs and downstairs heating and cooling airflow limits are set during installation Option used when bedrooms are located upstairs C365 uses the upstairs temperature sensor to control heating and cooling calls and directs more airflow upstairs One Model TS5 10 or two Model TS5 20 upstairs temperature sensors can be used Round or rectang...

Page 2: ...the battery cover downward and install the two AA batteries as shown R C W EQUIPMENT Y G Upstairs Sensor COM COM CLS CLS OPN OPN Upstairs Downstairs Install an R80CT damper in the duct supplying air to the upstairs and wire the terminals to the corresponding terminals on the C365T Install a second R80CT damper in the duct supplying air to the downstairs and wire it to the C365T Each damper uses 2 ...

Page 3: ... upstairs and downstairs dampers There are separate terminals for the upstairs and the downstairs dampers Multiple dampers can be used to construct the upstairs or downstairs zones Daisy chain terminals COM to COM OPN to OPN and CLS to CLS Use 2 conductor 18 or 20 gage thermostat cable to wire from the C365 Thermostat to the upstairs temperature sensor C365 Terminal C365 Terminal C365 Terminal R C...

Page 4: ... and Day NEXT ENTER AM Touch the UP DOWN keys to change the HOUR Touch NEXT to save the hour and go to change the minute CHANGE THE HOUR Touch the UP DOWN keys to change the MINUTE Touch NEXT to save the minute and go to change the day of the week CHANGE THE MINUTE Touch the UP DOWN keys to change the DAY OF THE WEEK Touch ENTER to save the day fo the week and return to thermostat operation CHANGE...

Page 5: ... L 5 0 Airflow Update Time A F t 1 to 20 minutes 2 ACCESSING INSTALLER OPTIONS To access the Installer Options and the hidden Enter key for 7 seconds until the first Option appears on the screen TOUCH HOLD Inside Tu Day Upstairs Auto Downstairs Airflow COOL Schedule AUTO FAN MENU MODE Cool Set To SYSTEM AM TOUCH HOLD and this key for 7 seconds to access the Installer Options Touch the keys to set ...

Page 6: ...e previous option UP DOWN NEXT ENTER BACK Option NEXT ENTER Touch the keys to select the cooling temperature when the space is vacant Touch to display the next option or to save the option and return to normal thermostat operation or touch the hidden key to return to the previous option UP DOWN NEXT ENTER BACK Option NEXT ENTER Cool Vacant Vacant Touch the keys to change the downstairs Inside temp...

Page 7: ...ion NEXT ENTER Cool Touch the keys to select the maximum allowable downstairs airflow in heating Touch to display the next option or to save the option and return to normal thermostat operation or touch the hidden key to return to the previous option UP DOWN NEXT ENTER BACK Downstairs Airflow Option NEXT ENTER Heat Touch the keys to select the maximum allowable downstairs airflow in cooling Touch ...

Page 8: ...stairs Airflow in Heating Upstairs Downstairs Airflow NEXT ENTER Heat To determine the maximum allowable downstairs airflow touch the key until the airflow is too great and causes noise or annoyance Increase the airflow using the key until it is acceptable This is the maximum allowable downstairs airflow in heating Record the airflow value DOWN UP Maximum Allowable Downstairs Airflow in Heating 05...

Reviews: