background image

8

ACCESSING THE TEST MENU

To access the Test Menu, 

 and 

 the hidden Next key for 7 

seconds until the fan test screen (Option 01) appears.

TOUCH

HOLD

The Test Menu is used to test the Indoor Fan Operation, Allowable 
Heating Airflow Limits and Allowable Cooling Airflow Limits.

Inside

Tu

Day

Upstairs

Auto

Downstairs

Airflow %

COOL

Schedule

AUTO

FAN

MENU

MODE

Cool

Set To

SYSTEM

AM

TOUCH

HOLD

 and 

 this key for 7 seconds

to access the Installer Options.

01-02  Testing Indoor Fan Operation

In Option 1, the Fan is Off.

Touch 

 to go to Option 2 

to turn on the indoor fan. Verify 
the fan is operating and 
delivering airflow to the 
upstairs and downstairs..

Touch 

 to go Testing 

Heating Airflow Limits.

NEXT

NEXT

Upstairs

Downstairs

Airflow %

Test

FAN

NEXT

ENTER

Upstairs

Downstairs

Airflow %

Test

FAN

NEXT

ENTER

03-04  Testing Heating Airflow Limits

In Option 3, the system is Off.

Touch 

 to go to Option 4 

to activate heating. Verify the 
equipment is operating.

To determine the maximum 
allowable upstairs airflow, 
touch the 

 key until the 

airflow is too great and causes 
noise or annoyance. Lower the 
airflow using the 

 key 

until it is acceptable. This is the 
maximum allowable upstairs 
airflow in heating. Record the 
airflow value.

NEXT

UP

DOWN

Upstairs

Downstairs

Airflow %

Test

NEXT

ENTER

Heat

Upstairs

Downstairs

Airflow %

NEXT

ENTER

Heat

This test is used to verify that the indoor fan is operating correctly.

This test is used to determine the maximum allowable upstairs airflow 
and the maximum allowable downstairs airflow in HEATING.

Maximum Allowable Upstairs Airflow in Heating

Upstairs

Downstairs

Airflow %

NEXT

ENTER

Heat

To determine the maximum 
allowable downstairs airflow, 
touch the 

 key until the 

airflow is too great and causes 
noise or annoyance. Increase 
the airflow using the 

 key 

until it is acceptable. This is the 
maximum allowable downstairs 
airflow in heating. Record the 
airflow value.

DOWN

UP

Maximum Allowable Downstairs Airflow in Heating

05-06  Testing Cooling Airflow Limits 

In Option 5, the system is Off.

Touch 

 to go to Option 6 

to activate cooling. Verify the 
equipment is operating.

To determine the maximum 
allowable upstairs airflow, 
touch the 

 key until the 

airflow is too great and causes 
noise or annoyance. Lower the 
airflow using the 

 key 

until it is acceptable. This is the 
maximum allowable upstairs 
airflow in cooling. Record the 
airflow value.

NEXT

UP

DOWN

This test is used to determine the maximum allowable upstairs airflow 
and maximum allowable downstairs airflow in COOLING.

Touch 

 to go to Testing Cooling Airflow Limits.

NEXT

Upstairs

Downstairs

Airflow %

NEXT

ENTER

Cool

Upstairs

Downstairs

Airflow %

ENTER

Cool

Maximum Allowable Upstairs Airflow in Cooling

To determine the maximum 
allowable downstairs airflow, 
touch the 

 key until the 

airflow is too great and causes 
noise or annoyance. Increase 
the airflow using the 

 key 

until it is acceptable. This is the 
maximum allowable downstairs 
airflow in cooling. Record the 
airflow value.

DOWN

UP

Maximum Allowable Downstairs Airflow in cooling

Touch 

 to end testing and return to normal thermostat 

operation.

ENTER

Upstairs

Downstairs

Airflow %

ENTER

Cool

Enter the maximum airflow limits using Options 17 
through 20 of the installer menu.

03-04  Testing Heating Airflow Limits (cont.)

Test

Test

Test

Test

NEXT

Test

NEXT

Summary of Contents for Comfort 365 C365T11

Page 1: ...ing only Cooling only Automatic Heating or Cooling Maximum upstairs and downstairs heating and cooling airflow limits are set during installation Option used when bedrooms are located upstairs C365 uses the upstairs temperature sensor to control heating and cooling calls and directs more airflow upstairs One Model TS5 10 or two Model TS5 20 upstairs temperature sensors can be used Round or rectang...

Page 2: ...the battery cover downward and install the two AA batteries as shown R C W EQUIPMENT Y G Upstairs Sensor COM COM CLS CLS OPN OPN Upstairs Downstairs Install an R80CT damper in the duct supplying air to the upstairs and wire the terminals to the corresponding terminals on the C365T Install a second R80CT damper in the duct supplying air to the downstairs and wire it to the C365T Each damper uses 2 ...

Page 3: ... upstairs and downstairs dampers There are separate terminals for the upstairs and the downstairs dampers Multiple dampers can be used to construct the upstairs or downstairs zones Daisy chain terminals COM to COM OPN to OPN and CLS to CLS Use 2 conductor 18 or 20 gage thermostat cable to wire from the C365 Thermostat to the upstairs temperature sensor C365 Terminal C365 Terminal C365 Terminal R C...

Page 4: ... and Day NEXT ENTER AM Touch the UP DOWN keys to change the HOUR Touch NEXT to save the hour and go to change the minute CHANGE THE HOUR Touch the UP DOWN keys to change the MINUTE Touch NEXT to save the minute and go to change the day of the week CHANGE THE MINUTE Touch the UP DOWN keys to change the DAY OF THE WEEK Touch ENTER to save the day fo the week and return to thermostat operation CHANGE...

Page 5: ... L 5 0 Airflow Update Time A F t 1 to 20 minutes 2 ACCESSING INSTALLER OPTIONS To access the Installer Options and the hidden Enter key for 7 seconds until the first Option appears on the screen TOUCH HOLD Inside Tu Day Upstairs Auto Downstairs Airflow COOL Schedule AUTO FAN MENU MODE Cool Set To SYSTEM AM TOUCH HOLD and this key for 7 seconds to access the Installer Options Touch the keys to set ...

Page 6: ...e previous option UP DOWN NEXT ENTER BACK Option NEXT ENTER Touch the keys to select the cooling temperature when the space is vacant Touch to display the next option or to save the option and return to normal thermostat operation or touch the hidden key to return to the previous option UP DOWN NEXT ENTER BACK Option NEXT ENTER Cool Vacant Vacant Touch the keys to change the downstairs Inside temp...

Page 7: ...ion NEXT ENTER Cool Touch the keys to select the maximum allowable downstairs airflow in heating Touch to display the next option or to save the option and return to normal thermostat operation or touch the hidden key to return to the previous option UP DOWN NEXT ENTER BACK Downstairs Airflow Option NEXT ENTER Heat Touch the keys to select the maximum allowable downstairs airflow in cooling Touch ...

Page 8: ...stairs Airflow in Heating Upstairs Downstairs Airflow NEXT ENTER Heat To determine the maximum allowable downstairs airflow touch the key until the airflow is too great and causes noise or annoyance Increase the airflow using the key until it is acceptable This is the maximum allowable downstairs airflow in heating Record the airflow value DOWN UP Maximum Allowable Downstairs Airflow in Heating 05...

Reviews: