PRODUCT IDENTIFICATION

 

 

 

2.1

 

Product Identification

 

 

The  product  name  plate  is  located  on  top of the connection flange.  The  name  plate  contains  the 
following: 

 

2.1.1  Marking 

 
 
 
 

 

 

 

  ECON logo (trademark) 

  Figure number 

  Serial number 

  Actuator type 

  Standard Hydraulic working pressure 

 

2.1.2  Certification 

 

 

LRS Type Approval Certificate 
 

 

2.2

 

Initial Inspection

 

 

Upon  the  receipt  of  the  actuator,  the  user  should  inspect  the  condition  of  the  product  and  ensure 
that the product specification stated on the name plate matches with the order sheet. 

 

  Remove the packing wrap or wooden box carefully. Inspect the product for any physical 

damage that may have occurred during shipment. 

  Check  the  product  specification  of the received product.  If  a  wrong  product  has  been 

supplied, please immediately report this to the distributing company. 

 

2.3 

Storage

 

 

Actuators must be stored in a clean, cool and dry area. The unit should be stored with the top cover 
installed and the connection ports plugged.  Storage must be off the floor, covered with a sealed dust 
protector. 

Summary of Contents for Fig. 21401

Page 1: ...ECON Hydraulic Actuator Fig 21401 21402 www eriks com Rev 0 April 2020 ECON HYDRAULIC LINEAR ACTUATOR Fig 21401 Spring Return Actuator type ESL Fig 21402 Double Acting Actuator type EDL Installation...

Page 2: ...External Parts for Double Single acting actuator 5 3 3 Globe Valve mounting 5 4 INSTALLATION HYDRAULIC REQUIREMENTS 6 4 1 Pre installation 6 4 1 1 Actuator application 6 4 1 2 Actuator orientation 6 4...

Page 3: ...s must read these instructions before the installation operation or maintenance of the ESL EDL Hydraulic Linear Actuators DANGER Refers to personal safety and alerts the user for danger and or injury...

Page 4: ...receipt of the actuator the user should inspect the condition of the product and ensure that the product specification stated on the name plate matches with the order sheet Remove the packing wrap or...

Page 5: ...ator for open closed position indication optional limit switches available Local Control Minimess quick connection couplers type SMK20 M16x2 Hydraulic connections inch BSP Ambient Temperature 20 C 4 F...

Page 6: ...eriks com Rev 0 April 2020 5 3 2 External Parts for Double Single acting actuator 3 3 Globe Valve mounting Position Item delivery 1 Actuator bottom flange actuator 2 O Ring mounting set 3 Valve mounti...

Page 7: ...available for submerged application up to 50 mt depth For submerged application a shaft cover should always be placed on top of the actuator to avoid water from penetrating the assembly through the a...

Page 8: ...ids and other hydraulic accessories Any type of mineral oil can be used the HLP type DIN 51524 2 is recommended Also many fire resistant fluids as HFC or polyglycole can be used Viscosity Range 15 200...

Page 9: ...s done by a spring The spring in ESL single acting actuators is of a mechanical type the spring housing contains a set of disc springs whenever a spring breaks the remaining springs take over and the...

Page 10: ...Installation Operation Manual Proven Quality since 1892 ECON Hydraulic Actuator Fig 21401 21402 www eriks com Rev 0 April 2020 9 6 ACTUATOR DIMENSIONS...

Page 11: ...Installation Operation Manual Proven Quality since 1892 ECON Hydraulic Actuator Fig 21401 21402 www eriks com Rev 0 April 2020 10...

Page 12: ...ity since 1892 ECON Hydraulic Actuator Fig 21401 21402 www eriks com Rev 0 April 2020 11 7 SPARE PARTS 7 1 Fig 21401 21402 EDL ESL Hydraulic Actuator position part description 1 Gasket Soft seal kit a...

Page 13: ...ear and of the same transparency and color as new oil The oil must be HLP DIN 51524 2 standard viscosity class VG 46mm2 sec DIN 51519 A spot oil test is suggested after 5 years no sludge and oil conta...

Page 14: ...nt check if the valve is not blocked If the valve is not blocked check for external oil leakage on the actuator Single acting actuator does not open Check Control pressure on the open side handpump co...