INSTALLATION & HYDRAULIC REQUIREMENTS 

4.1 

Pre-installation 

Note:   Prior to mounting, actuator assembly must be checked for any damage.

 

Damaged parts must be replaced by original spare parts.

 

Verify the actuator

s nameplate to ensure that actuator type, model number, force output are correct 

before installation or use. 
 
Check if the hydraulic control pressure corresponds with your system specification and the information on 
the actuator type plate.

 

 

4.1.1  Actuator application

ECON hydraulic actuators are used for operation of Globe valves and Valve Chests. The actuators are 
designed for severe operating conditions. For use in extreme conditions e.g. aggressive, corrosive 
environments it is recommended to mention this at the ordering stage, in order to verify if the actuator is 
suitable. The installation designer is responsible for the hydraulic actuator selection and must determine 
if the actuator is suitable for the working conditions. 

ECON hydraulic actuators are also available for submerged application up to 50 mt depth. 
For submerged application a shaft cover should always be placed on top of the actuator to avoid water 
from penetrating the assembly through the actuator shaft. 

 

 

4.1.2  Actuator orientation

The actuator can be installed in any position on to the valve, however it can be that the complete valve 
assembly is not allowed to be mounted in vertical position because of valve specifics. Check the valve 
specifications before installing. 

When the actuator has an Electric Hydraulic Powerpack there can also be restrictions in installing the 
assembly. Check the Powerpack specifications before installing.

 

 

4.1.3  Actuator Installation 

The handling and transportation of actuators must be carried out with extreme precaution and using the 
necessary and adequate means depending on their size and weight in order to avoid risks to the 
operators handling them. 

All ESL/EDL actuators will be delivered in combination with a globe valve or valve chest. This because of 
specialized mounting and adjusting procedure of the valve. 

Actuators should be installed in such a way that they are easy to access in order to do the periodic 
inspections and corresponding maintenance operations necessary to guarantee the performance qualities 
that they have been designed for. 

 

 

 

 

 

 

Summary of Contents for Fig. 21401

Page 1: ...ECON Hydraulic Actuator Fig 21401 21402 www eriks com Rev 0 April 2020 ECON HYDRAULIC LINEAR ACTUATOR Fig 21401 Spring Return Actuator type ESL Fig 21402 Double Acting Actuator type EDL Installation...

Page 2: ...External Parts for Double Single acting actuator 5 3 3 Globe Valve mounting 5 4 INSTALLATION HYDRAULIC REQUIREMENTS 6 4 1 Pre installation 6 4 1 1 Actuator application 6 4 1 2 Actuator orientation 6 4...

Page 3: ...s must read these instructions before the installation operation or maintenance of the ESL EDL Hydraulic Linear Actuators DANGER Refers to personal safety and alerts the user for danger and or injury...

Page 4: ...receipt of the actuator the user should inspect the condition of the product and ensure that the product specification stated on the name plate matches with the order sheet Remove the packing wrap or...

Page 5: ...ator for open closed position indication optional limit switches available Local Control Minimess quick connection couplers type SMK20 M16x2 Hydraulic connections inch BSP Ambient Temperature 20 C 4 F...

Page 6: ...eriks com Rev 0 April 2020 5 3 2 External Parts for Double Single acting actuator 3 3 Globe Valve mounting Position Item delivery 1 Actuator bottom flange actuator 2 O Ring mounting set 3 Valve mounti...

Page 7: ...available for submerged application up to 50 mt depth For submerged application a shaft cover should always be placed on top of the actuator to avoid water from penetrating the assembly through the a...

Page 8: ...ids and other hydraulic accessories Any type of mineral oil can be used the HLP type DIN 51524 2 is recommended Also many fire resistant fluids as HFC or polyglycole can be used Viscosity Range 15 200...

Page 9: ...s done by a spring The spring in ESL single acting actuators is of a mechanical type the spring housing contains a set of disc springs whenever a spring breaks the remaining springs take over and the...

Page 10: ...Installation Operation Manual Proven Quality since 1892 ECON Hydraulic Actuator Fig 21401 21402 www eriks com Rev 0 April 2020 9 6 ACTUATOR DIMENSIONS...

Page 11: ...Installation Operation Manual Proven Quality since 1892 ECON Hydraulic Actuator Fig 21401 21402 www eriks com Rev 0 April 2020 10...

Page 12: ...ity since 1892 ECON Hydraulic Actuator Fig 21401 21402 www eriks com Rev 0 April 2020 11 7 SPARE PARTS 7 1 Fig 21401 21402 EDL ESL Hydraulic Actuator position part description 1 Gasket Soft seal kit a...

Page 13: ...ear and of the same transparency and color as new oil The oil must be HLP DIN 51524 2 standard viscosity class VG 46mm2 sec DIN 51519 A spot oil test is suggested after 5 years no sludge and oil conta...

Page 14: ...nt check if the valve is not blocked If the valve is not blocked check for external oil leakage on the actuator Single acting actuator does not open Check Control pressure on the open side handpump co...

Page 15: ...tor Fig 21501 21502 www eriks com Rev 0 April 2020 14 If you have questions about this product Please contact the nearest ECON distributor You can find them on www eriks com ERIKS Flow Control Cypresb...

Reviews: