Ecolab Booster 12 Service Manual Download Page 16

14

Fig. 7                                    17465 

Fig. 8                                    17467 

Fig. 9                                    17469 

2. Maintenance 

The boosters do not require main-
tenance.
The fi lter must, however, be clea-
ned with regular intervals (approx. 
1-3 month) dependent on the 
water’s  lime contents.

2.1 Filter

 (Fig. 7)

Booster 6 and 12

1. Press ‘O’ on the control box to 

stop the Booster.

2. Close the ball valve for the inlet 

water.

3. Open a tap to make the system 

pressure free.

4. Check that the system is pres-

 su re free. Manometer must drop 
to 0.

5. De-assemble the fi lter and put it 

in a lime dissolving fl uid until the 
lime has dissolved.

    Remark. 

On Booster 6 the pres-

 su re switch must be de-assemb-
led fi rst.

6. Rinse the cleaned fi lter 

thoroughly and assemble it 
again.

Booster 24

The separate fi lter which is as-
sembled on the inlet pipe must be 
cleaned in accordance with the 
producer’s directions.
It is recommended to clean the 
Booster regularly.

2.2 Before a Long Break

If a long production break is plan-
 ned (more than 6 month) where 
the pump is emptied of water, it is 
recommended to safeguard the 
pump in the following way:
1. De-assemble the connection’s 

protection screen.

2. Spray a couple of drops of silico-

ne oil on the shaft between the 
cylinder head and connection.

The manual from the pump sup-
plier must furthermore be followed 
closely.

3. Start

Remark: 

The pump must be aired 

out and fi lled with water before 
start.

Remark: Check that the fl ow switch 
is placed correctly, see Fig. 8. The 
fl ow switch must be placed paral-
lel with the pipe so that the line 
comes out in the fl ow direction.

3.1 New System

To ensure a problem free start of a 
new system, the system must be 
fl ushed through and aired out:

Airing out of pipe system

1. Open the water supply to fl ush 

through and air out the system. 
Open the tap farthest away until 
no air or dirt come out. Then 
fl ush and air out the second 
farthest tap and continue until 
the closest tap has been fl us hed 
and aired out.

2. Assemble all Terminals/

Satellites.

Airing out of pump(s)

3. Loosenthe thermostat (A, fi g. 9) 

1-2 rounds until water and air 
come out.

    Remark:

 Never loosen the 

thermostat when the pump is 
running. The gasket may be 
damaged.

    Take care

 not to damage the 

thermostat’s line connection.

4. Tighten the thermostat device 

again.

5. Start the Booster so that the re-

maining air pockets can be pres-
sed up to the top of the pump.

    Check at the same time that 

the pump’s outfl ow di rect ion 
is correct. 

See the arrows on 

top of the motor.

6. Stop the Booster.
7. Loosen the thermostat 1-2 

rounds again and air out until 
only water comes out.

8. Tighten the thermostat again.
9. Start the Booster again.

Summary of Contents for Booster 12

Page 1: ...Servicemanual 1 10 Service Manual 11 20 Servicemanual 21 30 Manuel d entretien 31 40 Booster 6 Booster 12 Booster 24 DA EN DE FR...

Page 2: ...re Parts 19 9 Speci cations 20 Inhaltsverzeichnis DE 1 Beschreibung 21 1 1 Ablaufdiagramme 23 2 Instandhaltung 24 2 1 Filter 24 2 2 Vor einer l ngeren Betriebspause 24 3 Start 24 3 1 Neue Anlage 24 3...

Page 3: ...v gmodel Enkeltepumpesystem V g eller gulvmonteret Vandkapacitet Max 6 m3 time Flowstyret pumpen starter n r vandforbruget overstiger 3 l min Direkte start 1 Pumpe 2 Kontraventil 3 Kuglehane med unio...

Page 4: ...aturen overstiger 70o C 11 Transportsikring Booster 24 Fig 4 Dobbeltpumpesystem Kun gulvmonteret Vandkapacitet Max 24 m3 time Trykstyret start Med Y D eller direkte start 1 Pumpe 2 Kontraventil 3 Kugl...

Page 5: ...g 6 1 Pumpe 2 Kontraventil 3 Kugleventil Fig 5 17455b Fig 6 17383b 4 Pressostat 0 5 bar 5 Filter 6 Manometer 7 Flowafbryder 8 Kontrolboks 9 Termostat 4 Pressostat 0 5 bar 5 Pressostat 10 bar 6 Manomet...

Page 6: ...en problemfri start af et nyt anl g skal systemet gennem skylles og udluftes Udluftning af r rsystem 1 bn for vandtilf rslen for at gennemskylle og udlufte hele systemet bn det fjerneste udtag indtil...

Page 7: ...t vandudtag 4 Kontroller at manometeret er faldet til 0 5 1 Komponenter 5 1 1 Pumpe motor Pumpe motor er vedligholdelsefri Se dog afsnit 2 2 OBS P 60 Hz motorer skal den p kl bede sm revejledning f lg...

Page 8: ...il igen Afvent at temperaturen falder til under 60o C Er der tilstr kkelig vand forsyning 6 Fejlfinding 6 1 Anl gget starter ikke Trin 1 6 1 2 3 4 5 6 6 2 lampen p kontrolpanelet lyser Trin 1 5 1 2 3...

Page 9: ...der vand nok p syste met Kontroller at tilgangs trykket er mellem 2 4 bar Er filteret tilstoppet Rens filteret Roterer pumpen i den rigtige retning Tilkald elektriker Er pumpen ut t eller kommer der...

Page 10: ...betyder at pumpen startes uden forsin kelse n r flowsignalet er ON Kompressoren stoppes uden forsinkelse n r flowsignalet er OFF ALTO anbefaler ikke at der ndres p dipswitch indstillingerne med mindr...

Page 11: ...le Booster 6 12 24 Nr Beskrivelse Antal 311204 Printkort 1 0631030 Pressostat 0 5 bar 1 0601276 Termostat m adapter 1 0607659 Flowafbryder m stik 1 Booster 24 Nr Beskrivelse Antal Pressostat 1 10 bar...

Page 12: ...5 7 5 15 Styresp nding V 24 24 24 24 24 Motorv rn indstilling A 11 8 15 2 15 2 2 x 15 2 Forsikring A 25 20 tr g 20 16 tr g 25 25 63 V gt kg 103 95 150 150 250 Dimension H x B x D 1606x478x490 1326x600...

Page 13: ...mp system Wall or oor mounted Water capacity Max 6 m3 hour Flow controlled the pump starts when the water con sumption exceeds 3 l min Direct start 1 Pump 2 Check valve 3 Ball valve with union 4 Press...

Page 14: ...se of system fault 10 Thermostat Stops the pump if the temperature exceeds 70 C 11 Transport safeguard Booster 24 Fig 4 Double pum system Floor mounting only Water capacity Max 24 m3 hour Pressure con...

Page 15: ...essure switch 0 5 bar 5 Filter 6 Pressure gauge 7 Flow switch 8 Control box 9 Thermostat Booster 24 Figure 6 1 Pump 2 Check valve 3 Ball valve 4 Pressure switch 0 5 bar 5 Pressure switch 10 bar 6 Pres...

Page 16: ...d connection The manual from the pump sup plier must furthermore be followed closely 3 Start Remark The pump must be aired out and lled with water before start Remark Check that the ow switch is place...

Page 17: ...he inlet side 3 Open a tap 4 Check that the manometer has dropped to 0 5 1 Components 5 1 1 Pump motor Pump motor do not need mainte nance See section 2 2 however Remark On 60 Hz motors the at tached...

Page 18: ...below 60 C 6 Trouble Shooting 6 1 The system does not start Step 1 6 1 2 3 4 5 6 6 2 The lamp on the control panel lights up Step 1 5 1 2 3 4 5 Press 0 and then I on the control panel to restart the s...

Page 19: ...ean the lter Does the pump rotate in the right direction Call electrician Is the pump leaking or presenting jarring sounds 6 3 Too low or unstable pressure Step 1 4 1 2 3 4 Contact Ecolab s service or...

Page 20: ...setting is active meaning that the pump will start without any delay when the ow signal has turned ON The compressor will stop without any delay when the ow signal is OFF ALTO does not recommend you t...

Page 21: ...escription Number 311204 Printed circuit board 1 0631030 Pressure switch 0 5 bar 1 0601276 Thermostat with adapter 1 0607659 Flow switch with plug 1 Booster 24 No Description Number 0601374 Pressure s...

Page 22: ...rol voltage V 24 24 24 24 24 Motor overload protection A 8 8 15 2 15 2 2x 15 2 Protection A 25 20 time lag 20 16 time lag 25 25 63 Weight kg 70 95 140 150 230 Dimension H x W x D 1270x445x490 1326x600...

Page 23: ...System Zur Wandanbringung oder Bodenaufstellung Wasserdurchlauf max 6 m3 h Durchflussregelung Die Pumpe setzt sich in Betrieb wenn der Wasserverbrauch 3 l min bersteigt Direktstart 1 Pumpe 2 R ckschl...

Page 24: ...t bei Auftreten von Systemfehlern auf 10 Thermostat H lt die Pumpe an wenn die Temperatur 70 C bersteigt 11 Transportsicherung Booster 24 Abb 4 Doppelpumpen System Nur Bodenaufstellung Wasserdurchlauf...

Page 25: ...uckschalter 0 5 bar 5 Filter 6 Manometer 7 Durchlauf Sperrventil 8 Schaltkasten 9 Thermostat Booster 24 Abb 6 1 Pumpe 2 R ckschlagventil 3 Kugelventil 4 Druckschalter 0 5 bar 5 Druckschalter 10 bar 6...

Page 26: ...Sie die Schutzverkleid ung am Anschluss ab 2 Spr hen Sie einige Tropfen Silikon l auf die Achse und zwar zwischen Zylinderkopf und Anschluss Im brigen ist den Anweisungen des Pumpenherstellers sorgf l...

Page 27: ...Ecolab Warnhinweis Arbeiten an der Hauptstation d rfen nur vorgenom men werden wenn die Anlage vom Stromnetz getrennt und ohne Druck ist 1 Schalten Sie dazu den Hauptschalter aus 2 Schlie en Sie das K...

Page 28: ...utz schalter im Schaltkasten abgeschaltet Wieder einschalten Betr gt die Wassertempe ratur mehr als 70 C Warten Sie ab bis die Temperatur auf 60 C gefallen ist Ist die Wasserversorgung ausreichend ber...

Page 29: ...bar liegt Ist der Filter verstopft Filter reinigen Ist die Pumpe undicht oder gibt sie ungew hnli che T ne von sich 6 3 Zu niedriger oder schwankender Druck Schritte 1 4 1 2 3 4 Ziehen Sie einen Elekt...

Page 30: ...halter 5 in Position OFF ist ist die Kompressoreinstellung aktiv Damit wird die Pumpe ohne Verz gerung in Betrieb gesetzt werden wenn das Str mungssignal in Position ON ist Den Kompressor wird ohne Ve...

Page 31: ...ibung Anzahl 311204 Leiterplatte 1 0631030 Druckschalter 0 5 bar 1 0601276 Thermostat mit Adapter 1 0607659 Durchlauf Sperrventil mit Stecker 1 Booster 24 Nr Beschreibung Anzahl 0601374 Druckschalter...

Page 32: ...7 5 7 5 15 Steuerspannung V 24 24 24 24 24 Motorschutzschalter A 8 8 15 2 15 2 2x 15 2 Absicherung A 25 20 tr ge 20 16 tr ge 25 25 63 Gewicht kg 70 95 140 150 230 Abmessungen H x B x T 1270x445x490 1...

Page 33: ...unique Montage mural ou au sol Capacit en eau max 6 m3 heure Ecoulement contr l la pompe d marre lorsque la consommation d eau d passe 3 l min D marrage imm diat 1 Pompe 2 Clapet anti retour 3 Robinet...

Page 34: ...rmostat Arr te la pompe si la temp rature d admission d pas se 70 C 11 S curit transport Booster 24 Fig 4 Syst me double pompe Mod le x au sol uniquement Capacit en eau max 24 m3 heure D marrage par c...

Page 35: ...te de contr le 9 Thermostat Booster 24 Fig 6 1 Pompe 2 Clopet anti retour 3 Vanne isolement 4 Interrupteur pression 0 5 bar 5 Interrupteur pression 10 bars 6 Manom tre 7 Interrupteur d coulement 8 Bo...

Page 36: ...la connexion Le manuel fourni par le fabricant de la pompe doit en outre tre strictement suivi 3 D marrage Remarque avant le d marrage la pompe doit tre vid e de l air qu elle contient et remplie d ea...

Page 37: ...s pression 1 D clencher l interrupteur prin cipal 2 Fermer la vanne bille du c t de l admission 3 Ouvrir une vanne d coulement de l eau 4 Contr ler que le manom tre soit tomb 0 5 1 Composants 5 1 1 Po...

Page 38: ...anneau de contr le est allum e Etapes 1 5 1 2 3 4 5 Appuyer sur O et ensuite sur I sur le panneau de contr le pour remettre en route le syst me L installation est elle ali ment e en eau L installation...

Page 39: ...sens Faire appel un lectricien La pompe a t elle des fui tes ou fait elle des bruits anormaux 6 3 Pression trop basse ou instable Etapes 1 4 1 2 3 4 Contacter le service de d pannage d Ecolab Y a t il...

Page 40: ...est sur OFF le r glage du compresseur est actif Cela signi e que la pompe d marre sans retard lorsque le signal de ux est sur ON Le compresseur s arr te sans retard lorsque le signal de ux est sur OFF...

Page 41: ...it 311204 Circuit imprim 1 0631030 Interrupteur pression 0 5 bar 1 0601276 Thermostat avec adaptateur 1 0607659 Interrupteur d coulement avec prise 1 Booster 24 No Description Quantit 0601374 Interrup...

Page 42: ...15 Contr le tension V 24 24 24 24 24 Protection moteur installation A 8 8 15 2 15 2 2 x 15 2 Coupe circuit A 25 20 lent 20 16 lent 25 25 63 Poids kg 70 95 140 150 230 Dimensions H x L x P mm 1270x445x...

Page 43: ......

Page 44: ...2004 All rights reserved ALTO Danmark A S Blyt kkervej 2 DK 9100 Aalborg No 0617474d 06 2004 Printed in Denmark...

Reviews: