![Ecolab Booster 12 Service Manual Download Page 13](http://html1.mh-extra.com/html/ecolab/booster-12/booster-12_service-manual_2354471013.webp)
11
1. Description
The Booster systems are prepared
for supplying water under pressure
to a number of Ter min als/Satellites
from which the cleaning is carried
out.
The Booster systems are built of
solid materials, mainly stainless
steel.
A typical Booster installation with
Terminals/Satellites is illustrated in
Fig. 1:
•
Booster (1)
•
Mixing System (2)
•
Terminal/Satellite (3)
The systems are available in 3
sizes:
Booster 6
(Fig. 2, wall model)
•
Single pump system.
•
Wall or fl oor mounted.
•
Water capacity: Max. 6 m
3
/hour.
•
Flow controlled - the pump
starts when the water con-
sumption exceeds 3 l/min.
•
Direct start
1. Pump
2. Check valve
3. Ball valve with union
4. Pressure switch (protection
against dry running). Stops the
pump after 3 sec. if there is not
suffi cient water.
5. Filter
6. Pressure gauge
7. Flow switch
8. Control box
9. Control panel (is placed in the
cabinet on wall model)
•
O
Push-button. Stops the
system
•
I
Push-button. Starts the
system
•
∆
Lamp. Lights up in case of
system
fault
10. Thermostat. Stops the pump if
the inlet temperature exceeds
70°C
Fig. 1 17453c
Fig. 2 17466b
9
3
2
1
3
3
5
4
7
8
10
1
6
2
Summary of Contents for Booster 12