34
UNPACKING THE BOILER.
4.7.
Remove the packaging and the protective plastic.
4.8.
Remove the screws or bolts that fasten the stove to the pallet and remove it.
4.9.
If our model has a plastic protection, it must be removed before starting it.
4.10.
Remove exhaust blower protection.
Drawing 3
MATERIALS REQUIRED FOR INSTALLATION
MATERIAL
COMPLIANCE
PARTICULARS
It will be made of a material
resistant to the aggressive action
of the combustion products, to
condensation and to constant
temperatures of 300 °C. The
material will comply with the local
legislation for its application.
OBLIGATORY
•
ALL.
Aluminum, galvanized or iron
pipe.
PROHIBITED
•
ALL.
Insulated double wall pipe.
OBLIGATORY
•
Proximity to flammable materials.
•
When crossing a forge or partition.
•
Outdoor or brick-built chimney installation.
RECOMMENDABLE
•
Relative ambient humidity ≥ 60%.
•
Installation in a public facility.
•
Potentially accessible to children or people with
mental, physical or sensory disabilities.
T with outlet.
OBLIGATORY
•
ALL.
Clamp union.
OBLIGATORY
•
Install the exhaust spiral and gas outlet pipes,
thereby preventing anyone from disassembling or
moving the stove or pipe without tools.
Pipe anchors.
OBLIGATORY
•
Install the pipe, thereby preventing anyone from
disassembling or moving the stove or pipe
without tools.
Aluminium belt and silicone of
high temperature (300°C).
RECOMMENDABLE
•
If the pipe is not equipped with sealing rings
Pressure gauge.
RECOMMENDABLE
•
To compare the pressure of the circuit with which
the boiler indicates.
Expansion vessel.
OBLIGATORY
•
If the stove’s expansion tank is not big enough
according to specific calculations.
Buffer tank.
RECOMMENDABLE
•
Installation of special features such as radiant
floor, areas operated by thermostatic valves,
other stoves working in the same site, etc. The
device must be fitted with a buffer tank for proper
regulation.
Summary of Contents for CANTINA 24
Page 6: ...5 1 ESPECIFICACIONES T CNICAS 1 1 CANTINA SUPER CS 2012 08 1 2 HIDRO 24 HC 2015...
Page 30: ...29 1 TECHNICAL FEATURES 1 1 CANTINA SUPER CS 2012 08 1 2 HIDRO 24 HC 2015...
Page 53: ...52 1 SP CIFICATIONS TECHNIQUES 1 1 CANTINA SUPER CS 2012 08 1 2 HIDRO 24 HC 2015...
Page 77: ...76 1 SPECIFICHE TECNICHE 1 1 CANTINA SUPER CS 2012 08 1 2 HIDRO 24 HC 2015...
Page 101: ...100 1 ESPECIFICA ES T CNICAS 1 5 CANTINA SUPER CS 2012 08 1 6 HIDRO 24 HC 2015...