31
Installation instructions
Assembly sequence (Ref. fig. 32)
A) Mount the insulation (pos. 1) of the boiler body and secure
the 2 edges with the elastic straps (pos. 2) supplied in the
accessory box, hooking them to the external fabric part of the
insulation.
Perform a sufficient cut on the top part near the bulb holders.
B) Position the side panels (pos. 3a, 3b and 4a, 4b) with the lower
bend inside the L-shaped profile at the base of the boiler body
and hook the upper part to plate junction profiles.
To determine which is the right side and which is the left side,
refer to the cable gland plates on the front panels (pos. 5):
they must face the front of the boiler.
C) Fit the upper rear panel (pos. 7).
D) Rotate the cover of the panel board frontwards after having
removed the two screws on the side and insert the electric
inlet cables and the outlet probe capillaries through the slots
at the base.
Fix the panel board to the upper panel (pos. 9.)
Fit the upper panel pos. 9, complete with panel board, to the
two sides of the casing.
E) Insert into the conduits the bulbs of the instruments
as
indicated in fig. 35 and wire the panel board to the power line,
to the burner and to any pumps, etc.
Close the cover of the electric control board.
Guide the burner plug through the side plate (pos. 5) on the
preferred side and secure the cable with the cable gland
supplied.
Fasten the plates (pos. 5) to the sides of the casing.
Secure the electric cables coming out from the rear of the
boiler with the cable clamps, tightening them moderately.
F) Fit the upper longitudinal panels (pos. 10 and 11) hooking
them to the sides.
G) Fix the installation and boiler data plate (pos.12) to the side
panel after having degreased the relevant part with the
specific solvent.
The plates are included in the document envelope.
ECOMAX 3SC 1000-N÷2000-N
fig. 32
2
5
3a
3b
9
10
11
7
4a 5
1
4b
12
Summary of Contents for ECOMAX 3SC 1000-N