7
www.ecoflam-burners.com
EN
420010463703
M
Ai
r
G
as
313
160
170
144
142
141
120
150
314
34
9
151
155
100
143
T
o
be
supp
l
ied
by
the
insta
ll
er
T
o
be
supp
l
ied
by
the
insta
ll
er
107
143
Antivibration
coup
l
ing
144
G
as
governor
150
B
atterf
l
y
va
l
ve
151
G
as
train
Siemens
VGD
....
155
Pi
l
ot
gas
train
160
Kit
tightness
contro
l
(optiona
l
)
170
Kit
tightness
contro
l
for
pi
l
ot
gas
va
l
ve
(optiona
l
)
313
M
in.gas
pressure
switch
314
M
ax.gas
pressure
switch
(optiona
l
)
34
9
Air/gas
damper
motor
BURNER DESCRIPTION
Gas train - Kit - Accessories: assembly to the burner
MATCHING GAS TRAIN WITH DIAGRAM OF PRESSURE DROPS
ARE IN THE DEDICATED SECTION OF THIS MANUAL
VGD 20.503 Rp 2” / VGD 40.065 - 40.080 - 40.100 - 40.125
1. Main gas pipe
2. Ball valve
ACS
3. Antivibration coupling
ACS
5. Min gas pressure switch
EXPOR
T
GAS TRAIN
EN676
6. Safety gas valve + 10. Actuator
7. Working gas valve + 11. Actuator
8. Gas leakage control
KITTC *
9. Gas filter
ACS
KIT - MAX Gas pressure switch
KITPRES
ACS - Gas train connection pipe
GTCP **
Gas governor / Filter
FGDR - FILTER
Compulsory EN676
Tightness control
KITTC- Model
Compulsory > 1200 kW
Modulation Kit
KITMD-RWF 50
Probe-...
Max Pressure switch
KITPRES50
KITPRES150
Other accessories
Ecoflam gas trains are delivered separately for all gas and dual fuel burners and are available in different configurations:
Double gas valves with actuators and regulator VGD Siemens and min pressure ACS gas filter
1
2
3
9
11
8
10
5
6
7
!
WARNING:
EN676 compulsory kit and accessories in order to comply to the safety regulations. Additional accessories and kits
shall be installed by the installer in accordance to the local safety regulations and codes of practise.
HOW TO INSTALL THE GAS TRAIN INTO THE BURNER AND CALCULATE THE OVERALL DIMENSIONS
:
refer to the dimension page and the gas train manual for all detailed information
!
GTCP-...* WARNING:
in order to fit the gas train, the corresponding connection pipe must be ordered (GTCP size and fitting depend on the
burner and the gas train selected). Upon the installer responsibility it is mandatory to install additional support(s) in order to not overload the
burner body with the dead load of full gas train, accessories, piping and so on.
The burner body can stand just the gas valve and the piping between the gas valve and the body.
Summary of Contents for 3142132
Page 3: ...3 www ecoflam burners com EN 420010463703 CONFORMITY DECLARATION ...
Page 34: ...34 www ecoflam burners com EN 420010463703 APPENDIX Fluidics nozzle chart ...
Page 35: ...35 www ecoflam burners com EN 420010463703 APPENDIX Fluidics nozzle chart ...
Page 36: ...36 www ecoflam burners com EN 420010463703 APPENDIX Fluidics nozzle chart ...