     c. Connect the 5/16” pipe from the tap to the boiler outlet.
     d. Connect the 1/4” pipe from the tap to the Mains water supply      
         using the 350 kPa PLV and brass connectors supplied.        
     e. Push the end of the silicon tube on to the vent pipe of the unit.
5.  All pipes and tubes must not be extended and require a   

  

     continuous fall between tap and unit.
6.  Open tap until water is flowing from the spout.  
7.  Once water flows out of the tap, plug in the unit to a standard 3  
      Pin 10 Amp Power Socket and switch on the power. Make sure      
      the unit is positively earthed.
8.   After the power is turned on allow 20 minutes before testing and   
      using.
9.   Check for leaks at all connections. 
10. Position ‘Caution Boiling Water’ label close to the tap to alert  
       users to the water temperature.

Summary of Contents for EBE Express Series

Page 1: ...mportant This unit must be installed by an authorised plumber The unit to be connected in accordance with AS 3500 4 1 or AS NZS 3500 4 2 Do not turn on power to this boiler until water is flowing from the tap Please leave these instructions with the owner WHAT S IN THE BOX 1 x EBE Express Boiling Unit 1 x EBE 01 Express Boiling Tap 1 x EB FM 350 kPa PLV 1 x EB 316 Brass fitting kit 1 x Boiling Wat...

Page 2: ...he cartridge every 12 months The manufacturer recommends cleaning and servicing the unit every 24 months or every 12 months in hard water areas If the supplied power cord is damaged it must be replaced by an electrician The tap provided is a push through vented tap After dispenser water the tap will continue to dispense water until the spout is empty This ensure only water is dispensed each and ev...

Page 3: ...e extended and require a continuous fall between tap and unit 6 Open tap until water is flowing from the spout 7 Once water flows out of the tap plug in the unit to a standard 3 Pin 10 Amp Power Socket and switch on the power Make sure the unit is positively earthed 8 After the power is turned on allow 20 minutes before testing and using 9 Check for leaks at all connections 10 Position Caution Boi...

Page 4: ...y Faulty element Check and test power supply Replace element No water Water has been turned off Blocked water filter Check mains water supply Replace filter cartridge Water boilers Water chillers Boil Hot units Boil Hot Chill units Parts Accessories For more information about Ecoboil and our products visit our website or contact us Ecoboil Appliances Limited Phone 09 238 2209 Fax 09 282 4073 Mail ...