background image

Trouble Shooting

SYMPTOM

CAUSES

ACTION

Water overflowing 
from tap spout

Expansion chamber 
full

Low inlet pressure

Run tap for 5-10 minutes

Contact water supplier

Excessive steam 
from tap

Faulty element

Replace element

Water not hot

No power supply

Faulty element

Check and test power supply

Replace element

No water

Water has been 
turned off

Blocked water filter

Check mains water supply
        
                                                         
Replace filter cartridge

Water boilers

 

|

 Water chillers

 

|

 Boil/Hot units

 

|

 

Boil/Hot/Chill units

 

|

 

Parts & Accessories

For more information about Ecoboil and our products, 

visit our website or contact us:

Ecoboil Appliances Limited

Phone 09 238 2209

Fax 09 282 4073

Mail P.O. Box 940, Pukekohe 2340

Web www.ecoboil.co.nz

Summary of Contents for EBE Express Series

Page 1: ...mportant This unit must be installed by an authorised plumber The unit to be connected in accordance with AS 3500 4 1 or AS NZS 3500 4 2 Do not turn on power to this boiler until water is flowing from the tap Please leave these instructions with the owner WHAT S IN THE BOX 1 x EBE Express Boiling Unit 1 x EBE 01 Express Boiling Tap 1 x EB FM 350 kPa PLV 1 x EB 316 Brass fitting kit 1 x Boiling Wat...

Page 2: ...he cartridge every 12 months The manufacturer recommends cleaning and servicing the unit every 24 months or every 12 months in hard water areas If the supplied power cord is damaged it must be replaced by an electrician The tap provided is a push through vented tap After dispenser water the tap will continue to dispense water until the spout is empty This ensure only water is dispensed each and ev...

Page 3: ...e extended and require a continuous fall between tap and unit 6 Open tap until water is flowing from the spout 7 Once water flows out of the tap plug in the unit to a standard 3 Pin 10 Amp Power Socket and switch on the power Make sure the unit is positively earthed 8 After the power is turned on allow 20 minutes before testing and using 9 Check for leaks at all connections 10 Position Caution Boi...

Page 4: ...y Faulty element Check and test power supply Replace element No water Water has been turned off Blocked water filter Check mains water supply Replace filter cartridge Water boilers Water chillers Boil Hot units Boil Hot Chill units Parts Accessories For more information about Ecoboil and our products visit our website or contact us Ecoboil Appliances Limited Phone 09 238 2209 Fax 09 282 4073 Mail ...

Reviews: