background image

 

 

© 2017 EcoAir                                                                                    11                                                                         All rights reserved

 

 

  

IMPORTANT SAFETY INSTRUCTIONS

 

This  dehumidifier  is  not  intended  for  use  by  persons  (including  children)  with  reduced  physical,

 

sensory  or  mental  capabilities,  unless  they  have  been  given  supervision  or  instruction  concerning  use  of  the

 

dehumidifier by a person responsible for their safety.  Children should be supervised to ensure that they do not play 
with the dehumidifier.

 

READ & SAVE THESE IMPORTANT SAFETY INSTRUCTIONS FOR FUTURE REFERENCE

 

PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING.

 

 

WARNING!  

This dehumidifier is intended for domestic and light office use only.  Any other use 

is not  recommended by the manufacturer and may cause fire, electrical shocks or other inju-

ries to person or property.

 

 

When using electrical appliances, basic safety precautions should always be followed:

 

 

1.

 

Do not operate the dehumidifier where there is a damaged cord or plug or after it malfunctions or it 

has been dropped or damaged in any way.  Arrange for the dehumidifier to be examined or repaired 

by an authorised technician. 

 

2.

 

Always  keep  the  dehumidifier  in  an  upright  position  to  avoid  any  damage.    Place  the

 

dehumidifier on an even level surface during operation.

 

3.

 

Ensure the household voltage matches the rated specification for the dehumidifier before use. 

 

4.

 

Operate this dehumidifier in an ambient temperature between 5°C and 35°C. 

 

5.

 

Ensure  that  the  air  inlets  and  outlets  are  not  blocked  or  covered.    Do  not  insert  fingers  or  any

 

objects into the air inlet or outlet openings.

 

6.

 

Do  not  place  the  dehumidifier  too  close  to  curtains  or  other  objects,  keep  minimum  distance  of 

40cm.

 

7.

 

When  using  the  "LAUNDRY"  mode  to  dry  wet  clothes  efficiently,  keep  the  laundry  at  a  safe

 

distance from the dehumidifier to prevent water from dripping onto the dehumidifier. 

 

8.

 

Never  place  anything  on  top  of  the  dehumidifier  and  do  not  cover  while  in  use  or  before  it  cools 

down.

 

9.

 

To protect against electrical shocks, do not immerse or spray the dehumidifier or any of its parts in 

water.

 

10.

 

Never unplug the power cord without switching OFF the dehumidifier first.

 

 

11.

 

Always unplug the dehumidifier when not in use or when moving location.  To disconnect the dehu-

midifier from the power supply, grip the plug and pull from the power socket.  Never pull by the cord. 

 

12.

 

Always empty the water tank before storing the dehumidifier away. 

 

13.

 

Close  supervision  is  necessary  when  the  dehumidifier  is  used  in  the  presence  of  children  and 

 

pets. 

 

14.

 

Do not run power cord under carpeting, or cover with rugs or runners.  Arrange the cord away from 

areas where it may become a tripping hazard.

 

15.

 

Never operate or store the dehumidifier in direct sunlight. 

 

16.

 

Repairs must be carried out by an authorised technician, failure to do so may cause damage to the 

dehumidifier  or  injury  to  persons  or  property  and  void  the  warranty.    Always  insist  on

 

original spare parts.

 

17.

 

Avoid the using of an extension cable as they may overheat and cause a risk of fire. 

 

18.

 

Do not use the dehumidifier without the air filter.  Clean or replace the air filter regularly.

 

19.

 

Dispose of the water collected from the dehumidifier, this water is not drinkable.

 

20.

   

Do not leave the dehumidifier unattended in continuous drainage over a long period of time.

 

21.

 

At the end of its working life dispose the dehumidifier responsibly, in accordance with local by laws.

 

22.

 

Do not remove the water tank when running, this may cause water to leak. 

 

23.

 

Do not lead the end of continuous drainage hose outside when temperature is below 1°C.

 

24.

 

Do not use any heating application near the dehumidifier.

 

25.

 

Do not remove the power plug in wet hands.

 

26.

 

Damaged power cord must be replaced by qualified technicians or manufacturer.

 

Summary of Contents for ARION 26L

Page 1: ...ARION 26L POWERFUL ULTRA ENERGY EFFICIENT DEHUMIDIFIER UK ...

Page 2: ... be connected to the terminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN or GREEN YELLOW 4 Always ensure that the cord grip is positioned and fastened correc...

Page 3: ... musical instruments and artwork by drying it out too much HIGH HUMIDITY High humidity indoors causes damp and condensation The damp left by condensation can damage plaster wall paper furniture vehicles timber windows doors and clothes It can be harmful to our health when bacteria thrives causing mould and fungus MAINTAINING SAFE LEVELS OF HUMIDITY It is important to maintain a consistent humidity...

Page 4: ...et button to reset the filter clean indicator 6 Timer Button Select to set timer ON or OFF 7 Fan Speed Select for High Select for Medium or for Low fan speed 8 Set Humidity Button Press or to increase and decrease your humidity target settings The humidity ranges from 35 RH to 80 RH To access this mode you have to be in Manual mode Please see page 5 step 6 9 Auto Manual Button Select for access pr...

Page 5: ...xcess mois ture from all of the rooms in the house will migrate naturally towards the dehumidifier and be processed STEP 4 FAN MODE Low Select for low fan speed Use for quiet operation or when humidity has been reduced Highly recommended for night use Select for medium fan speed Use to combat excessive humidity in day time operation Highly recommended for day use Select for high fan speed Use for ...

Page 6: ...restart for approximately 3 minutes This is to protect the dehumidifier and is not a fault Operation will automatically restart after 3 minutes STEP 7 LAUNDRY CONTINUOUS CONTINUED FROM STEP 6 Press until the Laundry Continuous indicator light turn on Select desired fan speed The dehumidifier will operate con tinuously at its maximum dehu midification settings until setting is changed or the water ...

Page 7: ...filter is replaced every year for optimal performance and hygiene standards To purchase a replacement filter please visit www ecoairdirect com STEP 4 STORING YOUR DEHUMIDIFIER Turn OFF the dehumidifier wait for the fan to stop and unplug the dehumidifier from the power socket Leave the dehumidifier to drain for approximately one day Clean and dry the water tank Clean the filter and the dehumidifie...

Page 8: ...ter tank from the purpose made outlet see step 2 picture to the left side Clean the water tank Reinsert the water tank to the correct position as soon as possible to prevent water dripping from the dehumidifier NOTE Clean the water tank with clean water if needed Do not use detergent solvent abrasive or hot water to avoid damaging the water tank or float Do not remove or damage the float in the wa...

Page 9: ...o the dehumidifier 3 Run the drain hose downwards The drain hose can not be above the drainage joint This will cause flooding of your dehumidifier Make sure the drain hose is not pressed in any way 4 When removing the drain hose prepare a container to collect water from nozzle Note The drainage connector comes with a rubber gasket preinstalled If the rubber gasket came out from the drainage join p...

Page 10: ...tion 4 Take the casters out from the accessory box 5 Tilt the dehumidifier not more than 45 Align the caster shaft into the caster installation hole below the dehumidifier and push the castor upward till it fits properly 6 Repeat the same process as Step 5 for other 3 casters NOTE Keep the dehumidifier balance during installation to prevent the unit from falling 4 casters must be installed well be...

Page 11: ...revent water from dripping onto the dehumidifier 8 Never place anything on top of the dehumidifier and do not cover while in use or before it cools down 9 To protect against electrical shocks do not immerse or spray the dehumidifier or any of its parts in water 10 Never unplug the power cord without switching OFF the dehumidifier first 11 Always unplug the dehumidifier when not in use or when movi...

Page 12: ...sure the dehumidifier is on a flat even surface use a spirit level to check remove tank and replace correctly Water Leaking Damaged water tank Remove the water tank fill with water and place on a hard even surface to test for leaking The continuous drainage is clogged or loose Dehumidifier operating in colder envi ronment Check the continuous drainage hose and its connection Ensure room is within ...

Page 13: ...ction Rate at 26 7 C 60 RH 13 97 Litres per day Extraction Rate at 30 C 80 RH 26 Litres per day Water Tank Capacity 4 2 Litres Power Supply 220 240V 50Hz Power Input 257W Refrigerant R134a Net Weight 15 Kg Gross Weight 17 Kg Net Dimension W x H x D 351mm 492mm 260mm Gross Dimension W x H x D 407mm 530mm 329mm ...

Page 14: ...is guarantee Obligations for service and parts under this guarantee must be performed by EcoAir or an authorised service company Product features or specification described may be subject to change without notice C340 TWO 2 YEAR LIMITED GUARANTEE SAVE THIS GUARANTEE INFORMATION EcoAir guarantees this product free from defects in materials and workmanship for a period of Two 2 years from the date o...

Page 15: ......

Page 16: ... 2017 EcoAir All rights reserved C340 66129926723 www ecoair org ...