The antenna symbol is now permanently displayed.
•
This completes the installation and you can now adapt the pre-programmed
settings to your individual needs.
Please note:
•
Proceed as described above, if you wish to install further valve operating
mechanisms.
•
Afterwards, the number of radiators/valve operating mechanisms must be
set on the heating control (section 9.4.) and the security code must be
transmitted (section 9.5.).
52
ber of valve operating mechanisms that are used for the
heating control first, before you transmit the safety code
to the valve operating mechanism.
s¬¬ 4HE¬ VALVE¬ OPERATING¬ MECHANISM¬ ACKNOWLEDGES¬ RECEP
-
tion of the first radio log with an acoustic signal.
s¬¬ 4HE¬ANTENNA¬SYMBOL¬IS¬PERMANENTLY¬DISPLAYED
s¬¬ )NSTALLATION¬IS¬NOW¬lNISHED¬AND¬YOU¬MAY¬ADAPT¬THE¬PRE
-
programmed settings to your individual needs.
Proceed as described above for mounting of further valve
operating mechanisms. Next, you have to set the number of
valve operating mechanisms and transmit the safety code .
Adaptors for valves of other manufacturers may be pur-
chased separately (they are not enclosed in the scope of
supply).
RAVL
RAV
RA
After snapping-on the adap-
tors for the valves of the types
“RAV” and “RA” on the valve
body fix the adaptors with the
enclosed screws and nuts.
For valves of the type “RAV”
additionally put the cylindri-
cal extension piece onto the
valve pin.
%XAMPLES¬OF¬h$ANFOSSv¬ADAPTORS
14