Chapter II Page 3
1.
Dissolve of 30/40 grams of chemical protector (sodium metabisulfite) with the 5 liters
of water you set aside in a different container set the auxiliary valve (18) on aspiration
so that it can absorve the solution.
2.
Close the Seacock Valve (1), Start up the system by pressing “PRODUCTION”, and
just before the chemical protector and water solution from the tank runs out press
“STOP”. This means the entire circuit will contain this protecting solution.
Do not forget to shut off the seacock valve (1) as a security measure.
3.
When the unit is ready to be turned on once again, the valve (1) must set to the open
position and the valve (11) to the
“PRUEBA/TEST”
position so that the water produced
initially is rejected. Proceed as described in
I.6FIRST START-UP
(Chapter I Page 10).
Warning: sodium metabisulfite is a caustic product that may cause serious irritation to
the skin and mucus membranes. Take due precautions before handling, do not touch it
directly and always work in well-ventilated spaces.