For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561

TROUBLESHOOTING CHECKLIST (Caution: shut off power to pump)

PROBLEMS

PUMP DOES NOT RUN  

AND MAKES HUMMING 

SOUND 

 

 

 

 

PUMP RUNS BUT DOES  

NOT DELIVER WATER 

 

 

 

 

PUMP RUNS AND 

PUMPS 

OUT SUMP, BUT DOES  

NOT STOP

PUMP RUNS BUT ONLY 

DELIVERS A SMALL  

AMOUNT OF WATER 

 

 

 

 

FUSE BLOWS OR 

CIRCUIT BREAKER 

TRIPS WHEN 

PUMP STARTS 

 

 

 

MOTOR RUNS FOR A  

SHORT TIME, THEN 

STOPS

POSSIBLE CAUSES/SOLUTIONS

•  Line circuit breaker is off, or fuse is blown or loose 

•  Water level in sump has not reached turn-on level as indicated in  

 

  installation drawing. 

•  Pump cord is not making contact in receptacle. 

•  Float is stuck. It should operate freely in basin. 

•  If all of the above are OK, then the motor could be malfunctioning. 

•  Check if valve is installed backwards.  

 

 

 

 

  Arrow on valve should point direction of flow 

•  Discharge shut-off valve (if used) may be closed. 

•  Impeller or volute openings are fully or partially clogged. 

  Remove pump and clean. 

•  Pump is air-locked. Start and stop several times by plugging and  

 

  unplugging cord. Check for clogged vent hole in pump case.  

•  Inlet holes in pump base are clogged. Remove pump and clean the    

  openings. 

•  Vertical pumping distance is too high. Reduce distance or change the  

  discharge fittings of the pump. 

•  Float is stuck in up position. Be sure float operates freely in basin. 

•  Defective float switch. Replace float switch. 

 

 

 

•  Pump is air-locked. Start and stop several times by plugging in and    

  unplugging cord. Check for clogged vent hole in pump case. 

•  Vertical pumping distance is too high. Reduce distance or change the  

  discharge fitting of the pump. Inlet holes in pump base are clogged. 

  Remove pump and clean the strainer and openings. 

•  Impeller or volute openings are fully or partially clogged. 

  Remove pump and clean. 

•  Pump impeller is partially clogged with tar or paint, causing motor to   

  run slow and overload. Remove pump and clean. 

 

 
•  Pump impeller is partially clogged causing motor to run slow and  

 

  overload. Remove pump and clean. 

•  Motor stator may be defective. 

 

•  Fuse size or circuit breaker may be too small. (must be 15 amps). 

•  Impeller or volute opening are fully or partially clogged.

  Remove pump and clean .  

 

•  Inlet holes in pump base are clogged. Remove pump and clean the    

  openings. 

•  Pump impeller is partially clogged causing motor to run slow and  

 

  overload. Remove pump and clean. 

•  Motor stator may be defective. 

•  Impeller or volute openings are fully or partially clogged. 

  Remove pump and clean. Also clean the strainer if one is installed.

 

ELECTRICAL PRECAUTIONS

 

  Before servicing a pump, always shut off the main power breaker and  

 

  then unplug the pump. Make sure you are not standing in water and are 

wearing insulated protective sole shoes, under flooded conditions. Contact your local electric 

company or a qualified licensed electrician for disconnecting electrical service prior to pump 

removal

Summary of Contents for SUP64

Page 1: ...Owner s Manual Stainless Steel Submersible Utility Pumps General Safety 2 Specifications 3 Installation 4 Troubleshooting 5 Warranty 6 TABLE OF CONTENTS...

Page 2: ...t avoided will result in death or serious injury Indicates a hazard which if not avoided could result in death or serious injury Indicates a hazard which if not avoided could result in minor or modera...

Page 3: ...oded Basement Floors Window Wells Spas Cisterns and Sumps SPECIFICATIONS PERFORMANCE Capacity Cord Model HP Volt Ph Amps GPH at 0 Max Head Construction Impeller Length SUP64 1 4 115 1 2 5 1500 23 Stai...

Page 4: ...RE CONNECTION OVERLOAD PROTECTION Do not work on pump until power is unplugged Do not cut off ground pin or use an adapter fitting Do not use an extension cord The pump power cord should be connected...

Page 5: ...in basin Defective float switch Replace float switch Pump is air locked Start and stop several times by plugging in and unplugging cord Check for clogged vent hole in pump case Vertical pumping dista...

Page 6: ...eged defect Manufacturer will subsequently take corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty expires W...

Page 7: ...Manuel D Utilisation Pompe Submersible en Acier Inoxydable D usage G n ral S curit G n rale 8 Sp cifications 9 Installation 10 D pannage 11 Garantie 12 CONTENTS DU TABLEAU...

Page 8: ...tiquettes de s curit manquantes ou endommag es Une pompe de puisard est un appareil lectrique con u pour fonctionner dans les environnements humides en soi TOUJOURS UTILISEZ UNE ATTENTION EXTREME lor...

Page 9: ...r Flooded Basement Floors Window Wells Spas Cisterns and Sumps SPECIFICATIONS PERFORMANCE Capacity Cord Model HP Volt Ph Amps GPH at 0 Max Head Construction Impeller Length SUP64 1 4 115 1 2 5 1500 23...

Page 10: ...tilisation d une rallonge INSTALLATION b Couper la broche de terre ou utiliser un raccord d adaptateur c Travailler sur la pompe ou l interrupteur lorque il est branch d Retirer le carter de moteur d...

Page 11: ...t verrouill e air D marrez et arr tez plusieurs fois par brancher et d brancher le cordon V rifiez le venteau bouch dans la bo te de pompe La distance de pompage vertical est trop lev e R duisez la di...

Page 12: ...expiration de la garantie La garantie n est pas transf rable et ne s applique pas aux produits utilis s dans des applications commerciales de location Les termes et les conditions g n raux Les limitat...

Page 13: ...Manual De Operaci n Bomba De Uso General Sumergible De Acero Inoxidable Seguridad general 14 Especificaciones 15 Instalaci n 16 Soluci n de problemas 17 Garant a 18 TABLA DE CONTENIDO...

Page 14: ...no se evita podr a causar la muerte o lesiones graves indica un riesgo que si no puede evitarse puede provocar lesiones leves o moderadas AVISO indica pr cticas no relacionadas con lesiones personales...

Page 15: ...Flooded Basement Floors Window Wells Spas Cisterns and Sumps SPECIFICATIONS PERFORMANCE Capacity Cord Model HP Volt Ph Amps GPH at 0 Max Head Construction Impeller Length SUP64 1 4 115 1 2 5 1500 23...

Page 16: ...anular la garant a a El uso de un cable de extensi n INSTALACI N b Cortando el conector de tierra o usando un adap tador apropiado c trabajando en la bomba o cambiando mientras est enchufado d Extrac...

Page 17: ...s veces enchufando y desenchufando el cable Compruebe que el orificio de ventilaci n est obstruido en el caso de la bomba Distancia de bombeo vertical es demasiado alto Reducir la distancia o cambiar...

Page 18: ...onto como sea razonablemente posible No se aceptar n solicitudes de servicio si se recibe m s de 30 d as despu s del vencimiento de la garant a La garant a no es transferible y no se aplica a producto...

Reviews: