(h)  All piping must be clean and free of all  

 

    foreign matter to prevent clogging. 
(i)   Pump will be inadequate if suspension liquids  

    contain solid particles larger than 1/4” 

     

   

Verify that the voltage and    

     

   

frequency of the pump shown 

on the nameplate corresponds to those available on 

the mains. The installer must make sure that the  

electric system is grounded in accordance with code. 
•  For outdoor use it is necessary to use cable with  
 a 

length of  at least 8’. The plug and connection  

  should be protected from water splashes. Before  

  using the pump, always inspect it visually  

 

  (especially power cable and plug) 

•  Do not use pump if it is damaged 

•  If the pump is damaged, have it inspected by an  

  authorized service center. 

•   Make sure that electric connections are protected  

  from flooding. Protect the plug and the power   

  cable from heat or shape edges. 

   

     

   

The power cable must be re 

     

   

placed by qualified personnel 

only. Grounding: The plug of the power cable has a 

double grounding contact, so that grounding can be 

performed by simply inserting  the plug. 

This pump series has a built in thermal protection 

switch. The pump stops if an overload condition  

occurs. The motor restarts automatically after it has 

cooled down.

INSTALLATION

ELECTRICAL WIRE CONNECTION

OVERLOAD PROTECTION

Do not work on pump until power is unplugged. 
Do not cut off ground pin or use an adapter  

fitting. 
Do not use an extension cord.   

 

 

The pump power cord should be connected to a 

separately fused, grounded line with a minimum  

capacity of 15 amps.  
1. Before installing or servicing this pump, be    

  certain pump source is disconnected. 
2. Installation and electrical wiring must adhere  

  to state and local codes and must be   

 

  completed before priming pump. Check  

 

  appropriate community agencies, or contact   

  local electrical and pump professionals. 
3. Call an electrician when in doubt. Pump  

 

  should be connected to a separate 15  

 

  amp circuit breaker or 15 amp fuse block.    
  Note that plugging into existing outlets may    

  cause low voltage at motor. This could cause  

  blown fuses, tripping of motor overload or    

  burned out motor. 
4. For maximum safety, connect pump to a circuit  

  equipped with a fault interrupter device when  

  positioning the pump’s grounding wire. 

5. Voltage of power supply must match the    

  voltage of the pump.  
6. Before installing pump, clear of any water,    

  debris or sediment.  

 

 

 

7.  The following may cause severe damage to   

  pump and will void the warranty. 
   (a) Using an extension cord. 
 

 

(b) Cutting off the ground pin or using an    

       adapter fitting. 
  (c) Working on pump or switch while  

      plugged in.

  (d) Removing motor housing, unscrewing    

    impeller, or otherwise removing impeller    

   seal. 
  (e) Running the pump continuously. 
  (f)  Pumping chemicals or corrosive liquids,    

    other than motor oil. 
  (g) Pumping gasoline or other flammable liquids

4

For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561

Summary of Contents for PUP57

Page 1: ...Owner s Manual High Capacity Transfer Utility Pump General Safety 2 Specifications 3 Installation 4 Troubleshooting 5 Warranty 6 TABLE OF CONTENTS PUP57 PUP60...

Page 2: ...t avoided will result in death or serious injury Indicates a hazard which if not avoided could result in death or serious injury Indicates a hazard which if not avoided could result in minor or modera...

Page 3: ...pas lakes or ponds SPECIFICATIONS PERFORMANCE Capacity Cord Solids Model HP Volt Ph Amps GPH at 0 Max Head Construction Impeller Length Pumped PUP57 1 2 115 1 8 0 1500 101 Cast Iron Thermoplastic 10 P...

Page 4: ...t cut off ground pin or use an adapter fitting Do not use an extension cord The pump power cord should be connected to a separately fused grounded line with a minimum capacity of 15 amps 1 Before inst...

Page 5: ...Reduce distance or change the discharge fitting of the pump Remove pump and clean the strainer and openings Impeller or volute openings are fully or partially clogged Remove pump and clean Pump impell...

Page 6: ...y alleged defect Manufacturer will subsequently take corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty expi...

Page 7: ...PUP57 PUP60 S curit G n rale 8 Sp cifications 9 Installation 10 D pannage 11 Garantie 12 CONTENTS DU TABLEAU Manuel D Utilisation Pompe Utilitaire De Grande Capacit...

Page 8: ...tiquettes de s curit manquantes ou endommag es Une pompe de puisard est un appareil lectrique con u pour fonctionner dans les environnements humides en soi TOUJOURS UTILISEZ UNE ATTENTION EXTREME lor...

Page 9: ...MANCES Capacit T te Longueur Solides Mod le HP Voltage Ph Amp res GPH at 0 Maximale Construction Impelleur du Cordon Pomp s PUP57 1 2 115 1 8 0 1500 101 Cast Iron Thermoplastic 10 PUP60 1 2 115 1 6 5...

Page 10: ...e ou utiliser un raccord d adaptateur c Travailler sur la pompe ou l interrupteur lorque il est branch d Retirer le carter de moteur d visser l impelleur ou autrement retirer le sceau de l impelleur e...

Page 11: ...yez les ouvertures La hauteur de pompage vertical est trop importante R duisez la distance ou changez les raccords de refoulement de la pompe Le flotteur est bloqu en position haute Il doit bouger lib...

Page 12: ...pr s l expiration de la garantie La garantie n est pas transf rable et ne s applique pas aux produits utilis s dans des applications commerciales de location Les termes et les conditions g n raux Les...

Page 13: ...Seguridad general 14 Especificaciones 15 Instalaci n 16 Soluci n de problemas 17 Garant a 18 TABLA DE CONTENIDO Manual De Operaci n Bomba De Alta Capacidad Uso General PUP57 PUP60...

Page 14: ...no se evita podr a causar la muerte o lesiones graves indica un riesgo que si no puede evitarse puede provocar lesiones leves o moderadas AVISO indica pr cticas no relacionadas con lesiones personales...

Page 15: ...akes or ponds ESPECIFICACIONES Y RENDIMIENTO Capacidad onguitud s lidos Modelo HP Volt Ph Amps GPH at 0 Max Cabeza Construcci n Impulsor de cable bombeados PUP57 1 2 115 1 8 0 1500 101 Cast Iron Therm...

Page 16: ...N b Cortando el conector de tierra o usando un adap tador apropiado c trabajando en la bomba o cambiando mientras est enchufado d Extracci n de la carcasa del motor desenroscan do impulsor o retirar...

Page 17: ...scarga de la bomba Los orificios de entrada de la base de la bomba est n obstruidos Extraiga la bomba y limpie el filtro de malla y las aberturas Las aberturas de la voluta o impulsor est n total o pa...

Page 18: ...a tan pronto como sea razonablemente posible No se aceptar n solicitudes de servicio si se recibe m s de 30 d as despu s del vencimiento de la garant a La garant a no es transferible y no se aplica a...

Reviews: