INSTALLATION

For parts or assistance, call ECO-FLO Customer Service at 1-877-326-3561

Wire Splicing

Splice wire to motor leads using only copper wire for

connections to pump motor and control box.

1. Tapered splice (Wire sizes No. 8 and larger):

  A. Cut motor lead staggering lead and wire length so   

  that second lead is 2” longer than first lead and third    

  lead is 2” longer than second.

  B. Cut off power supply wire ends. Match colors and    

  lengths of the wires to colors and lengths of motor leads.

  C. Trim installation back 1/2” from supply wire and motor  

  lead ends.

  D. Insert motor lead ends and supply wire ends into butt  

  connectors. Match wire colors between supply wires and  

  motor leads.

  E. Using crimping pliers, indent butt connector lugs to  

  attach wire.

  F. Cut electrical “Scotchfil™” or equivalent insulation    

  putty into three equal parts and form tightly around butt  

  connectors. Be sure Scotchfil™ overlaps insulted part of  

 wire.

  G. Using #33 Scotch™ or equivalent tape, wrap each   

  joint tightly; cover wire for about 1-1/2” on each side of  

  joint. Make four passes with the tape. When finished you  

  should have four layers of tape tightly wrapped around  

  the wire. Press edges of tape firmly down against the   

 wire.

  NOTICE: Since tightly wound tape is the only means   

  of keeping water out of splice, efficiency of splice will   

  depend on the care used in wrapping the tape.

  NOTICE: For wire sizes larger than No. 8, use soldered  

  joint rather than Scotchfil™ putty.

2. Heat shrink splice

 [for wire sizes #14, 12 and AWG (2,3 and 5mm)]

  A. Remove 3/8” insulation from ends of motor leads and  

  power supply wires.

  B. Put plastic heat shrink tubing over motor leads

  between power supply and motor.

  C. Match wire colors and lengths between power

  supply and motor.

  D. Insert supply wire and lead ends into butt connector  

  and crimp. Match wire colors between power supply and  

  motor. Pull leads to check connections.

  E. Center tubing over butt connector and apply heat

  evenly with torch (match or lighter will not supply enough  

 heat).

  NOTICE: Keep torch moving. Too much concentrated

  heat may damage tubing.

3. Mechanical Splice Kit with plastic insulators (for 14, 12

and 10 Gauge AWG Wire (2, 3 and 5mm):

  A. Cut motor leads staggering lead and wire length so

  that 2nd lead is 4” (101.6mm) longer than 1st lead and

  3rd lead is 4” (101.6mm) longer than second.

  B. Cut wire ends matching colors and lengths of wires

  between power supply and motor.

  C. Trim insulation back 1/2” (12.7mm) from power supply

  wire and motor lead ends.

  D. Unscrew plastic caps from insulators. Place a cap

  and neoprene gasket sleeve on each wire to be spliced.

  E. Slide insulator body onto one wire end.

  F. Insert wire end into butt connector and crimp. Match  

  wire colors between power supply and motor

  G. Center insulator body over splice and slide gasket

  sleeves into body as far as they will go. Screw caps

  onto insulator body and tighten by hand for a strong,

  waterproof splice.

Power Supply Wire Installation

1. To test submersible, momentarily (no more than 5  

 

seconds) connect it to proper power supply. Power supply 

frequency and voltage must match motor name plate 

frequency and voltage to within ±10%.

2. Fasten power supply wire leads securely to pump 

discharge section; leave 4-5” (100-125mm) of slack in leads 

at this point. Securely fasten leads to plastic pipe within 

6” (150mm) of the pump discharge section. Use centering 

guides to protect wire and pipe from rubbing well casing.

3. Connect copper ground wire to motor bracket. Ground

wire must be as large as wires supplying current to motor. 

Consult current Canadian Electrical Code and local codes 

for grounding information.

4. Most 4” pumps have an eyelet on the pumps discharge

for attaching a rope to assist in lowering into and pulling the 

pump from the well. Attach a nylon rope of adequate length 

to eyelet

5. Do not use submersible power supply wires supplied by 

pump manufacturer to lower or lift pump. When lowering 

pump into well use only the rope and/or discharge pipe, 

secure supply wires to discharge pipe at 10 ft. (3M) 

intervals with Scotch™ #33 or equivalent electrical tape. 

DO NOT damage pump wires.

NOTICE:

To avoid dropping pump down well or damaging wires or 

splices, NEVER allow pump wires to support weight of 

pump.

Summary of Contents for EFSUB10-102

Page 1: ...mp Selection 2 3 General Safety 4 Electrical 5 6 Installation 7 9 Troubleshooting 10 Repair Parts 11 Warranty 12 TABLE OF CONTENTS 2Wire Models EFSUB5 102 1 EFSUB5 102 EFSUB7 102 EFSUB10 102 3 Wire Mo...

Page 2: ...pump pumped ie 10 GPM In some counties this information is recorded at the health office or other offices of the county and or the driller may have retained the information in the driller s file You n...

Page 3: ...e motors have 3 wires running from the motor 2 to provide electric service and 1 ground wire The motor controls are in the motor in the well 3 wire motors have 4 wires running from the motor 3 to prov...

Page 4: ...reezing may damage system leading to injury or flooding Allowing pump or system components to freeze will void warranty Can shock burn or cause death To avoid dangerous or fatal electric shock hazard...

Page 5: ...ble Pump Motors Table 2 Recommended Fusing Data 60 Hz Single Phase 2 Wire Submersible Pump Motors To avoid over heating wire and excessive voltage drop at motor be sure wire size is sufficient per NEC...

Page 6: ...HP Submersible Motor Control Follow color coding when connecting submersible motor control Yellow to Y Red to R Black to B Two wire pumps have two power supply wires Red Black and one ground wire Subm...

Page 7: ...eep torch moving Too much concentrated heat may damage tubing 3 Mechanical Splice Kit with plastic insulators for 14 12 and 10 Gauge AWG Wire 2 3 and 5mm A Cut motor leads staggering lead and wire len...

Page 8: ...und Let run until water is clear of sand or silt To check solids in water fill a glass from pump and let solids settle out 7 When water is completely clear at 1 3 setting open gate valve to approximat...

Page 9: ...down the well to the pump s motor B Clamp or weld or both if necessary this bonding conductor to the grounding means provided with the pump which will be the equipment grounding terminal the groundin...

Page 10: ...otor control nameplate or on circuit diagram inside submersible motor control cover Check wire size against chart Page 3 Check all tank connections with soapsuds for air leaks Check plumbing for leaks...

Page 11: ...dition of screen Pull pump and examine check valve Make sure system is clear of obstructions and pump is in solid water and operating normally Check for presence of gas in well water Make sure ports a...

Page 12: ...0502 1 2HP 3W 230V EFSUB0503 3 4HP 2W 230V EFSUB0751 3 4HP 3W 230V EFSUB0752 1HP 2W 230V EFSUB1001 1HP 3W 230V EFSUB1002 1 Pump End 1 2HP 10GPM EFSUB0506 1HP 20GPM EFSUB1004 1HP 10GPM EFSUB1003 1 Suct...

Page 13: ...efect Manufacturer will subsequently take corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty expires Warrant...

Page 14: ...ction de la pompe 16 S curit G n rale 17 Electrique 18 19 Installation 20 22 D pannage 23 Parts de R paration 24 Garantie 25 CONTENTS DU TABLEAU 2Wire Models EFSUB5 102 1 EFSUB5 102 EFSUB7 102 EFSUB10...

Page 15: ...Dans des comt s cette information est enregistr e au bureau de sant ou aux autres bureau du comt et ou le foreur peut avoir conserv les informations dans le dossier du foreur Vous avez besoin d une co...

Page 16: ...e et 1 fil de terre Les commandes du moteur se trouvent dans le moteur dans le puits 3 fils moteurs ont 4 fils en cours d ex cution partir du moteur 3 pour fournir un service lectrique et 1 fil de ter...

Page 17: ...ndations Permettre la pompe ou des composants du syst me de geler la garantie sera annul e Peut lectrocuter br ler ou causer VOLTAGE DANGEREUX la mort Pour viter le risque de choc lectrique dangereux...

Page 18: ...ase 2 Wire Submersible Pump Motors Pour viter le fil de surchauffe et le voltage excessif de d poser au moteur soyez s r que la taille du fil est au moins aussi grande que la taille cit e dans le tabl...

Page 19: ...ar 1 HP la Commande du Moteur Submersible Suivez le codage de couleur lors de la connexion de contr le du moteur submersible Jaune pour Y Rouge pour R Noir pour B Deux fil pompes ont deux fils de la s...

Page 20: ...op de chaleur concentr e peut endommager le tube 3 Le Kit d Epissure M canique avec les isolateurs en plastique pour 14 12 et10 Fil de Jauge d AWG 2 3 et 5mm A Coupez le plomb du moteur d calant la lo...

Page 21: ...e de sable ou de limon Pour v rifier les solides dans l eau remplissez un verre de pompe et laissez les solides se d posent 7 Lorsque l eau est tout fait clair sur 1 3 appareil ouvrez la vanne environ...

Page 22: ...puissance en cours d ex cution dans le puits au moteur de la pompe B Pincez ou soudez ou tous les deux si c est n cessaire cette liaison du conducteur la terre a veut dire qu il est fourni avec la po...

Page 23: ...du couvercle de commande du moteur submersible V rifiez la taille du fil avec le tableau Page3 V rifiez toutes les connexions du r servoir avec la mousse de savon pour d tecter les fuites d air V rifi...

Page 24: ...NOM Pompe Fin 1 1 2 3 4 1 2HP 2W 230V EFSUB0502 1 2HP 3W 230V EFSUB0503 3 4HP 2W 230V EFSUB0751 3 4HP 3W 230V EFSUB0752 1HP 2W 230V EFSUB1001 1HP 3W 230V EFSUB1002 1 2HP 10GPM EFSUB0506 1HP 20GPM EFS...

Page 25: ...ra accept e si elle est re ue plus de 30 jours apr s l expiration de la garantie La garantie n est pas transf rable et ne s applique pas aux produits utilis s dans des applications commerciales de loc...

Page 26: ...de bombas 28 Seguridad general 29 El ctrico 30 31 Instalaci n 32 35 Soluci n de problemas 35 Piezas de reparaci n 36 Garant a 37 TABLA DE CONTENIDO 2Wire Models EFSUB5 102 1 EFSUB5 102 EFSUB7 102 EFSU...

Page 27: ...ba bombeado es decir 10 GPM En algunos condados de esta informaci n es registrada en la oficina de salud u otras oficinas del condado y o el perforador puede haber retenido la informaci n en el expedi...

Page 28: ...vicio el ctrico y 1 cable de tierra Los controles de motor est n en el motor en el pozo Motores de 3 hilos tienen 4 cables que van desde el motor 3 para proporcionar el servicio el ctrico y 1 cable de...

Page 29: ...dando lugar a lesiones o inundaciones Permitir componentes de la bomba o del sistema se congele se anular la garant a Puede causar choque quemaduras o la muerte Para evitar choques el ctricos peligros...

Page 30: ...co 2 cables de Motores de bombas Para evitar el sobrecalentamiento del alambre y la ca da de tensi n excesiva en el motor el tama o del cable sea segura es al menos tan grande como el tama o que apare...

Page 31: ...v s de 1 HP Motor Sumergible control Siga c digo de colores cuando conecte el control motor sumergible Amarillo a Y Rojo a R Balck a B Las bombas de dos conductores tienen dos cables de alimentaci n r...

Page 32: ...rar suficiente calor AVISO Mantenga la antorcha en movimiento El ex ceso de calor concen trados pueden da ar la tuber a 3 Empalme mec nico Kit con aislantes de pl stico de 14 12 y 10 AWG de alambre 2...

Page 33: ...v lvula de compuerta en esta posici n mientras el agua bombea en el suelo Deje correr el agua hasta que est libre de arena o limo Para comprobar s lidos en agua llene un vaso de la bomba y dejar que...

Page 34: ...pasa por el pozo al motor de la bomba B abrazadera o soldadura o ambos si es necesario de este conductor de uni n a la tierra provista con la bomba que ser la terminal de tierra del equipo el conducto...

Page 35: ...35 SOLUCI N DE PROBLEMAS Para piezas o asistencia llame a ECO FLO Servicio al Cliente al 1 877 326 3561...

Page 36: ...ba Protecci n del cable Pantalla de succi n 1 1 1 2 3 4 1 2HP 2W 230V EFSUB0502 1 2HP 3W 230V EFSUB0503 3 4HP 2W 230V EFSUB0751 3 4HP 3W 230V EFSUB0752 1HP 2W 230V EFSUB1001 1HP 3W 230V EFSUB1002 1 2H...

Page 37: ...nsporte y gastos imprevistos Las reclamaciones en virtud de esta garant a deber ser presentada por contacto y devolver el producto a la f brica inmediatamente despu s del descubrimiento o cualquier su...

Reviews: