STEP 1:
Mount the Control/Alarm Panel to the battery case
using the four mounting screws provided. Battery
case has four mounting holes predrilled for easy
installation of control panel.
For best results, use a Group 24, marine battery.
Battery dimensions should not exceed : 9” high
(including post) x 12” long x 6-1/2” wide.
YOUR BATTERY BACKUP SUMP PUMP SYSTEM IS READY.
STEP 2:
Insert marine battery into battery case. Attach
the RED and BLACK wires from the back of the
control/alarm panel to each of the battery clamps
provided. Then connect battery clamps to the
battery. RED WIRE to the POSITIVE (+) terminal
and the BLACK WIRE to the NEGATIVE (-)
terminal.
STEP 4:
Turn the alarm switch on the control/alarm panel to the OFF position and plug the 12 volt transformer in
a GFCI outlet. If a GFCI outlet is unavailable, have an electrician install one for you. Once proper power
is supplied, turn the alarm switch to the on position. Then plug the primary sump pump to its power
source.
Pre-drilled
Mounting Hole
Power
Pump Cord
Float
Switch
6-1/2”
12”
9”
BATTERY & CONTROL/ALARM PANEL ASSEMBLY
STEP 3:
Plug in the designated components to the control/
alarm panel, A battery backup pump, B the float
switch, C and the 12 volt transformer.