Eco Air ECO906SQ Installation Manual Download Page 5

2

WARNING

      Read these SAFETY PRECAUTIONS carefully to ensure correct installation.
      Precautions are classified as WARNING and CAUTION.  Ensure all precautions are 
      observed as they are important to ensure your safety.

Failure to observe precautions may cause grave consequences.

      

Failure to follow any WARNING is likely to result in grave consequences such as death or serious injury.

The following symbol used in this manual should be strictly oserved:

NEVER ATTEMPT

.

CAUTION

Failure to follow any CAUTION may result in grave consequences in some cases.

WARNING

1)  Installation should be carried out by a technically competent person, the dealer or specialist professional
      

Improper installation may cause water leakage, electrical shock, or fire.

2)  Installation should be according to instructions given in this manual. Incomplete installation may cause 
     water leakage, electrical shock, or fire.

3) Only use the accessories, parts supplied and specified.  Use of other parts may cause failure,  water 
    leakage, electrical shock, or  fire.

4)  Install the air conditioner on a solid and firm base that can withstand the weight of the unit.  An inadequate
     base or incorrect installation may cause injury and damage if the unit falls off the base.

,

5)  Electrical work must be carried out in accordance with the installation manual and the national electrical
     wiring standards, regulations and code of conduct. A dedicated circuit must be used and never share the 
     power supply with another appliance. Insufficient capacity or incorrect electrical work may cause electrical 
     shock, or fire.
6)  Use the specified cables for electrical connections between indoor and outdoor units. Firmly clamp the 
     cables so that no external stress is placed on the terminal. Incorrect connection or clamping  may cause 
     terminal heating, electric shock or fire.
7)  After connecting the interconnecting cables, properly arrange the cables and the cable covers so that there
     is no undue pressure on the electrical covers or panels. Incorrect cover installation may cause terminal 
     overheating, electrical shock or fire.

8)  When carrying out piping connection, take care not to let air substances other than the specified 
     refrigerant  into refrigeration cycle. Any presence of air or other foreign substance in the refrigerant
     circuit causes abnormal pressure rise or rupture, resulting in injury.

9)  An earth and an earth leakage breaker  must be installed.  Do not earth the unit to a utility pipe, arrester 
     or telephone earth. Incomplete earth may cause electrical shock or fire.  A high surge current from 
     lightning or other sources may cause damage to the air conditioner.

CAUTION

3) Ensure measures are taken so to prevent the outdoor unit from being used as a shelter by small animals
    Small animals making contact with electrical parts can cause malfunction, smoke or fire. 

1)  Do not install the unit in a place where there is any likely exposure to flammable gas leakage. If the
     gas leaks and builds up around the unit, it may catch fire.

2)  Carry out drainage piping according to the instructions of this manual. Inadequate piping may cause
     flooding and leakage.

SAFETY  PRECAUTIONS

10) After the installation is completed, check to make sure that no refrigerant is leaking out. The refrigerant
     is toxic gas if exposed to flames.

Summary of Contents for ECO906SQ

Page 1: ...Before using your air conditioner please read this manual carefully and keep it for future reference R410A SPLIT SERIES DC INVERTER QUICK COUPLING Models ECO906SQ ECO1206SQ ECO1806SQ...

Page 2: ...ust be connected to the terminal which is marked with the letter N or coloured BLACK The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED...

Page 3: ...ke back the old appliance for disposal when you replace with a new product C Old products contain valuable resources which should be recycled as scrap metal Wild disposal of waste in forests and lands...

Page 4: ...nsure that they do not play with the air conditioner If the power cord is to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accorda...

Page 5: ...se electrical shock or fire 6 Use the specified cables for electrical connections between indoor and outdoor units Firmly clamp the cables so that no external stress is placed on the terminal Incorrec...

Page 6: ...e free from the possibility of flammable gas leakage in a nearby place Avoid places near a bedroom and the like so that the noise will not be an annoyance Ensure any local authority permission is soug...

Page 7: ...loor Two of the A B and C directions should be free from obstructions CAUTION Self tapping screw B ST2 9x10 C H Remote controller holder 7 8 12cm above Air Filter 12cm above 15cm above 1 2 3 Remote Co...

Page 8: ...nd corresponding mounting points on the installation plate Dimensions are in mm unless otherwise stated 1 Determine hole positions according to the diagram detailed in Fig 5 Drill one 1 hole 90mm slan...

Page 9: ...on 3 Drainage Installation 1 Run the drain hose sloping downward to ensure condensation water is being drained externally any rise in the drain hose will prevent condensation water to flow externally...

Page 10: ...erly by putting the unit lengthwise along the wall or using a dust or shield plates In coastal or windy area install the unit to prevent the exposure to strong winds If mounting on wall brackets the i...

Page 11: ...that the handle on the male coup ling is in a reclined positio n away from the mating male coupling Step 2 Retract the Release Sleeve on female coupling insert the male coupling located on the indoor...

Page 12: ...ion Step 4 Retract the Release Sleeve on the female coupling to release the male coupling half from the female half Step 5 To seal and protect from dust reinstall the protective cap and plug Electrica...

Page 13: ...or details 4 The test operation may last about 30 minutes Model Power supply Input Rated Amp Switch Fuse 16000Btu h NOTE The supply voltage can not be less than the rate voltage of the air conditioner...

Page 14: ...MEMO Date of installation Purchased from Dealer Name Date of purchase Model number Serial number...

Page 15: ...ing from a faulty installation is specifically excluded This unit must be operated under conditions as recommended at voltages indicated on the unit Any attempts made to service or modify the unit by...

Reviews: