Follow the steps as indicated below:
1
Brew group in the beginning.
2
Use a flat screwdriver to pry out the
shower screen and the group
gasket.
3
The shower screen and the gasket
are now nearly removed.
4
Remove the shower screen and the
gasket completely.
5
Keep the new spare parts ready at
hand (the rounded side of the
group gasket with ECM print faced
upwards to the brewing group).
6
Clean the group with a brush.
Lock the shower screen firmly into
the gasket.
7
Insert the shower screen into the
brew group.
8
Take the filter holder without filter.
9
Clamp the filter holder into the
brew group.
10
Then, move the filter holder until
the shower screen is locked firmly
into the gasket.
11
Now you can easily lock the filter
holder into place.
12
The group is ready for use.
The machine can be used again, as described on page 24 of the instruction manual.