Bedienungsanleitung / User Manual SYNCHRONIKA
ENGLISH
21
3.2 Technical data
Voltages:
EU: 230 V
UK: 230 V
New Zealand: 240 V
Australia: 240 V
US: 115 V
Japan: 100 V
Power:
1.200 W – 1.400 W
Water tank:
ca. 3.0 l
Measurements:
B x T x H / 340 mm x 475 mm x 420 mm
Measurements with filter holder:
B x T x H / 340 mm x 590 mm x 420 mm
Weight:
31 kg
3.3 PID-Temperature Control
The function of a PID-Temperature Control is to regulate the temperature of both boilers. The temperature of the
boilers are programmable and controlable independently from each other. You have the possibility to extract coffee
at varying temperatures. PID stands for “proportional-integral-derivative” The temperature plays an integral role in
coffee preparation.
The PID-control displays the temperature of the coffeboiler and the steamboiler alternately. The position of the
period indicates which kettle´s temperature is currently being displayed.
Temperature coffee boiler (t1, here 92°C)
-Period in the 1st position
Temperature steam boiler (t2, here 124°C)
-Period in the 3rd position
4 MACHINE INSTALLATION
The installation is to be carried out exclusively by qualified specialists, according to the following
instructions and in compliance with valid laws and local regulations.
4.1 Preparation for installation
•
Place the machine on an even and stable surface.
•
Never place the machine on hot surfaces.
•
Place the machine on a water-proof surface, as the machine may at some point leak water.
4.2 Electrical connection
•
Make sure that the local main voltage supply corresponds to the information given on the type
plate on the front panel of the espresso machine.
•
Plug the machine into a grounded socket only and do not leave it unattended.
•
Do not roll or bend the power cord.
•
Do not use an extension cord/ do not use a multiple socket.
Summary of Contents for synchronika