Bedienungsanleitung / User Manual/ Handleiding/
Руководство
по
эксплуатации
SYNCHRONIKA
ENGLISH
29
It is recommended to leave the filter holder in the brew group, keeping it warm for optimum
temperature for coffee dispension.
If you would like to plumb your machine, installation through a qualified service technician is
required.
6.2 Programming via the PID-display
During normal operations, the temperatures of the coffee boiler (t1, left dot on the display) and the steam boiler (t2,
right dot on the display) are indicated alternately.
The controls are factory pre-set so that both boilers are heated consecutively, whereby the coffee boiler (t1) has
priority. This means that the steam boiler (t2) is activated only after the programmed temperature of the coffee
boiler has been reached.
The machine can also be set up by your specialist dealer so that both boilers can heat at the same time.
Higher energy consumption is possible in this case.
Switch the machine on in order to activate both boilers (switch in position “2”).
The temperature of either boiler is of no importance in programming. Both
heaters are inactive during programming.
2. Press
+
and
–
at the same time until ‘t1’ (coffee boiler) appears on the
display,
3. Press
+
in order to progress to the submenu of ‘t1’ and to change the
temperature value. The nominal temperature value is displayed.
4. Quickly press
-
to decrease
+
to increase
the nominal temperature value.
5. Please wait a short while after having set the nominal temperature value;
‘t1’ will be displayed
6. Press
-
in order to display ‘t2’ (steam boiler). If you would like to change just
‘t2’ and leave ‘t1’ unchanged, press
–
after step 2 in order to progress directly to
‘t2’ and skip ‘t1’. Continue with step 7.
7. Press
+
in ord
er to progress to the submenu of ‘t2’ and to change the