*Given the following alarm codes, troubleshooting should only be done by a Amano Pioneer Eclipse
Factory Certified Technician. A programming handset may be required for troubleshooting.
Number of
Flashes
Description
Possible Cause
1 (fast)
Low Battery Voltage
The battery needs charging or there is a bad connection to the battery.
Check the connections to the battery. If the connections are good, try
charging the battery.
1 (medium)
Handle lever engaged at key on
Disengage the handle lever, key off and key back on to clear
1 (slow)
Machine Time Out
The machine has been left with the key on. Turn the key off and then back
on again.
2
Motor Disconnected
The motor has a bad connection. Check all the connections and leads
between the motor and the controller.
3
Motor Wiring Trip
The motor has a short circuit to a battery. Check all the connections and
leads between the motor and the battery.
6
I
nhibit Active
The controller is being inhibited from driving. Check the state of the Inhibit
unputs.
7
Throttle Trip
A throttle trip is indicated. Make sure that the throttle is in the rest position
before switching on the vehicle.
8
Possible Controller Trip
A possible controller trip is indicated. Make sure that all connections are
secure.
9
Solenoid Brake Trip
The parking brakes have a bad connection. Check the parking brake and
motor connections. Make sure the controller connections are secure.
10
High Battery Voltage
An excessive voltage has been applied to the controller. This is usually
caused by a poor battery connection. Check the battery connections.
Alarm Codes (Traction Only)
Summary of Contents for PE300BU
Page 1: ...UHS Battery Burnisher PE300BU Operator s Manual ...
Page 2: ......
Page 12: ...12 Controls and Instruments 2 4 7 3 1 5 6 2 1 3 4 Machine Components ...
Page 25: ...25 Electrical Schematic Traction ...
Page 26: ...26 Connections Traction ...
Page 43: ......