Page
14
of
23
REFILLING THE ECO-100
•
After deactivating pneumatic control handle (Deadman), keep nozzle firmly in hands and
pointed away from any person until abrasive flow has completely stopped.
•
When the operator releases the Deadman, the ECO-100 will automatically depressurize. This
will deactivate the blaster and depressurize the blast pot.
•
You will hear a loud exhaust sound when the pressure control button is deactivated. This is
the exhaust valve relieving the air pressure from the vessel.
•
After the blaster has fully depressurized, the plunger will drop.
•
You can now refill the vessel with your desired abrasive.
•
After the ECO-100 is refilled with abrasive reactive the pressure control button. This will re-
pressurize the blast pot to the previously set pressure.
EMPTYING THE VESSEL
Removing the Manual Plunger Valve:
•
Turn off compressor, depressurize and disconnect air hose.
•
Disconnect the (blue) blast pressure airline going to the manual plunger valve by pushing
down on the PTC ring on the media valve fitting.
•
Disconnect blast hose coupler, twin lines and water line.
•
Spin the media valve counterclockwise to unthread the valve from the vessel.
•
This will allow all abrasive to drain out.
•
Capture media into bucket for reuse.
•
Before reinstalling media valve confirm threaded on the ECO-100 are free of abrasive and
debris.
•
Rethread media valve back into place and reconnect blast pressure air line.
Summary of Contents for ecoflex Eco-100 PRO
Page 17: ...Page 17 of 23 COMPRESSOR REQUIREMENTS ...