![Eclipse Algas-SDI P120 Operation & Maintenance Manual Download Page 49](http://html.mh-extra.com/html/eclipse/algas-sdi-p120/algas-sdi-p120_operation-and-maintenance-manual_533936049.webp)
Troubleshooting
6-50
Algas-SDI Operations & Maintenance Manual P/N 52632
Thermocouple Tests
NOTE
Thermocouples seldom fail. Most thermocouple problems will be
broken wires or loose connections or shorted wires due to
insulation problems.
Using the following
Figure 27
as a guide, check for frayed or loose wiring and
correct color-coding of the connections.
Figure 27 - Thermocouple Tests
Thermocouple Tests.dxf
NOTE
The two thermocouples are interchangeable. You may trade the
wires of #2 thermocouple and #1 thermocouple for aid in
troubleshooting. Color coding of each pair must be observed.