ECL-ACC997 / ECL-ACC999

V121203

   

   

Adding and Deleting Tag

Delete All Tags

Input      123456      (or Master Code)

 → 

29     29

Delete a Single Tag

Input      123456      (or Master Code)

 → 

10     SSSSS     EEEEE

[e.g.] Delete User Address: 00058

       

Access programming mode

 → 

10     00058     00058

9

9

Delete a batch of Tags

Input      123456      (or Master Code)

 → 

10     SSSSS     EEEEE

[e.g.] Delete User Address: 00101~00245

       

Access programming mode

 → 

10     00101     00245

9

9

Add Single Tag or Random tags

Input      123456      (or Master Code)

 → 

19     UUUUU     00001

     → 

Present the tag(s) with Controller 

(single tag or random numbered cards one by one)

 → 

Done

[e.g.] 2 readom cards with user addresses No. 100 and No. 101:

       

Access programming mode

 → 

19     00100     00001

     → 

Present the tags one by one

 → 

Done

Input      123456      (or Master Code)

 → 

19     UUUUU     QQQQQ

     → 

Present the tags 

(Present the tag with the 

lowest number

 first.)

 → 

OK

Add the Sequential tags

[e.g.] User Address NO.101 to NO.120 have 20 pcs of sequential tags:(62312~62332)

       

Access programming mode

 → 

19     00101     00120

     → 

Close Tag into RF Area

(only use the tag 

NO.62312

)

 → 

OK

Tag Information

SITE CODE

CARD CODE

SITE CODE

CARD CODE

Changing the Master Code

Access programming mode

 → 

09     PPPPPPRRRRRR         [Input the 6-digit new master code twice.]

[e.g.] If want to changing the Master Code= 876112, input  

   

123456

     → 

09     876112876112

Exiting

Input

Access programming mode

 → 

00     NNN     MMM     AAA    

[NNN= Node ID: 000~254; MMM=ECL-ACC997 / ECL-ACC999 Door NO.:1~255; AAA=WG Reader Door NO.:1~255

B. Changing the Node ID of Reader

Programming

A. Entering and Exiting Programming Mode

Entering

Input      123456      or      PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input  

   

876112

     → 

Access programming mode

Enable device

Access programming mode

 → 

20     U     DDD        U= Enable target unit

 (0=AR-ECL-ACC997 / ECL-ACC999,1=Reader)

 [Please refer to function default value for details.]

[e.g.] If the 

ECL-ACC997 / ACL-ACC999

 set to 

exit reader

WG Reader

 set to 

access reader

Access programming mode

 → 

20     0     128       

 → 

20     1     192       [Please refer to function default value for details.]

Enable/Disable auto open zone

Access programming mode

 → 

20     U     DDD       U= Enable target unit

(0=ECL-ACC997/ECL-ACC999,1=Reader) [Please refer to function default value for details.]

[e.g.] If the 

ECL-ACC997/ECL-ACC999

 set to 

Enable aut open zone

Access programming mode

 → 

20     0     004       [Please refer to function default value for details.]

[e.g.] If the 

WG Reader

 set to 

Enable aut open door without presenting card

Access programming mode

 → 

24     1     128       [Please refer to function default value for details.]

Enable/Disable auto open door without presenting card

Access programming mode

 → 

24     U     DDD       U= Enable target unit

 (0=AR-ECL-ACC997 / ECL-ACC999,1=Reader)

 [Please refer to function default value for details.]

[e.g.] User address from 00152 to 00684 enable the anti-pass-back function:

 

26     00152     00684     0

Enable card user

Access programming mode

 → 

26     SSSSS     EEEEE     P       

SSSSS= starting user address; EEEEE= ending user address [P=0 Enable/ P=1 Disable/ P=2 Reset]

[e.g.] ECL-ACC997 / ACL-ACC999 (

without WG reader

), to set second time zone which could be passed only at 9:30am to 4:20pm on Mon and Fri.

Access programming mode

 → 

08     10     02     09301620     01000100      

→  

setting is completed

Setting up access time

Access programming mode

 → 

08     MW     NN     HHMMhhmm     7123456H       [M=ECL-ACC997 / ACL-ACC999; W=Reader(0=disable,1=enable); 

NN: 16 sets of auto-open zone (NN=00~15); HHMMhhmm=Starting time to ending time; 7123456H= 7 days of week + Holiday (F= 0: disable; 1: enable)]

Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or somewhere wants to 

monitor not only the access but also exit condition.

Door will keep opening after first man flashing card.  When the reader is stand-alone, supporting only 16 sets of auto-open zone by device setting. 

Auto-open zone can extend up to unlimited sets by Networking.

C. Anti-pass-back

D. Auto Open Zone

Summary of Contents for ECL-ACC997

Page 1: ...ED Output 5V 20mA Max 3 Brown Green LED Output 5V 20mA Max Door Output 4 Blue White Transistor Output Max 12V 100mA Open Collector Active Low Wiegand 5 Thin Green Wiegand DAT 0 Input 6 Thin Blue Wiega...

Page 2: ...ontroller RTE RTE RTE RTE RTE POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC Magnet Lock Connect to Ele...

Page 3: ...C997 ACL ACC999 set to exit reader WG Reader set to access reader Access programming mode 20 0 128 20 1 192 Please refer to function default value for details Enable Disable auto open zone Access prog...

Page 4: ...digit arming code Enable particular device Induct valid card Input 4 digit arming code U or Disable particular device Induct valid card Input 4 digit arming code U or Input 5 digit user address Input...

Page 5: ...n where finger can easily be placed 2 Use the middle or ring finger of either hand for the registration authentication purpose 3 Put your finger tip first to the top of the unit and lower the finger d...

Page 6: ...sticker on Ethernet Module device Please revise IP address you want and then click Update button After updating the IP please re connect the Web Browser by new IP address User Password The password c...

Page 7: ...r code settings 09 PPPPPPRRRRRR PPPPPP New master code RRRRRR Repeat the new master code Suspend or delete tags Suspend 10 SSSSS EEEEE Suspend Delete SSSSS starting user address EEEEE ending user addr...

Page 8: ...99 En Disable Skip Finger Tag 40 F NNNNN EEEEE First 40 1 NNNNN EEEEE Then 40 3 NNNNN EEEEE Function Default Value 20 U DDD Default Value Function Option Value Application Time Attendance 0 Yes 1 No 0...