background image

Instructions for use

 

                                                              

 

 

 

antistatic protective garment against heat risks, electric arc and liquid chemicals 

 

Good

PRO

 

SF1

 

Oliver 

 

PPE -  category III 

 

 

Manufacturer:  

Good

PRO

, s.r.o., Dukelska 1247, 334 01 Prestice, Czech republic, www.goodpro.cz

 

 

Material:

  

65% Lenzing FR, 22% aramid, 12% polyamid, 1% Belltron, weight 250 g/m²

 

 
Description: 

The  garment  is  made  of  the  fabric  with  Lenzing  FR

®

 

fibres,  and  provides  not  only  protection,  but  also  excellent  comfort  thanks  to  its 

extraordinary  thermoregulation  properties.  The  fabric  contains  conductive  fibres  which  safely  take  away  static  electricity.  The  fabric  also 
protects against the negative effects of the exposure to arc flash and ensures a limited protection against liquid chemicals.

 

 

EN ISO 11612: 

In  contact  with  flame  or  small  burning  particles  the  material  becomes  carbonized,  but  the  fire  does  not  spread 

  it  therefore  prevents 

injuries caused by burning clothes. In case of any accidental splashes by liquid chemicals and/or flammable liquids, the wearer must retreat 
immediately and take off the garment carefully. Avoid any contact with skin. The contaminated garment must be cleaned or discarded. 

EN ISO 11611: 

This  protective  garment  is  in  compliance  with  Standard  EN  ISO  11611,  class  1.  It  ensures  protection  against  welding  hazards  and  similar 
related processes. This type of protective clothing is intended to protect the wearer against fire, radiant heat, molten-metal splashes, short 
contact time with flame, radiant heat from the arc, and minimizes the possibility of electrical shock by short-term, accidental contact with 
live electrical conductors at voltages up to approximately 100 V d.c. in normal conditions of welding. Sweat, soiling or other contaminants 
can  affect  the  level  of  protection  provided  against  short-term  accidental  contact  with  live  electric  conductors  at  these  voltages.  The 
contamination by flammable substances can lead to the degradation of the level of flame resistance. The protective garment of class 1 can 
be used for flame welding, WIG (Wolfram-Inert-Gas) and MIG (Metal-Inert-Gas) welding, plasma arc welding and spot welding, brazing and 
MMA (Manual-Metal-Arc) welding as well as for oxygen torch cutting, plasma torch cutting and the use of resistance welding machines. The 
protective garment, class 2, can be used for MIG welding, MAG and MMA welding, oxygen torch cutting, plasma torch cutting, metallization 
as  well  as  welding  in  confined  spaces  or  above  the  head.  The  protective  garment  should  be  regularly  checked.  Any  damage  caused  by 
intensive UV  radiation, radiant heat, flying sparks  or molten-metal droplets can lead to  the degradation of the protective features  of the 
garment. For further information, please, check standard EN ISO 11611, Annex A, B. 

EN 1149-5: 

This  protective  garment  conforms  to  the  requirements  of  standard  EN  1149-5  and  is  designed  to  prevent  incendiary  discharges.  The 
garment can be used on the premises with flammable atmosphere only in compliance with the valid standards and regulations governing 
the protection against static electricity. The wearer dressed in electrostatic dissipative protection garment must be well-grounded through a 
resistance  lower  than  10

8

 

Ω 

we  also  recommend  to  wear  suitable  footwear.  Electrostatic  dissipative  protection  garment  must  be  well-

fastened,  do  not  take  it  off  in  the  close  proximity  of  flammable  or  explosive  atmospheres  or  when  handling  flammable  or  explosive 
substances.    Electrostatic  dissipative  protection  garment  must  not  be  used  in  oxygen  enriched  flammable  atmosphere  without  the  prior 
approval  of  the  responsible  safety  officer.  The  excessive  wear  and  use,  damage,  laundering  or  possible  contamination  can  influence  the 
antistatic properties of the garment. When used, electrostatic dissipative protective clothing should permanently cover all non-complying 
materials during normal use (including bending and movements). 

EN 13034: 

This garment has a special FC treatment, which provides a limited protection against liquid chemicals. FC treatment must be repeated after 
20 wash cycles 

 use the waterproofing agent HYDROB FC (see the instructions). The design of the personal protective clothing with  limited 

protective performance against liquid chemicals  covers the lowest level of chemical protection 

 it protects against potential exposure to 

small quantities of spray, liquid aerosols or low pressure or low volume splashes against which a complete liquid permeation  barrier (at a 
molecular level) is not required. The garment is designed to protect against chemicals, type 6. It has been tested as a set. 

EN 61482-1-1: 

This personal protective garment is in compliance with standard EN 61482-1-1, which specifies the test method for measuring the thermal 
resistance of suits against the thermal hazards of an electric arc. Determination of the arc rating (ATPV) 

EN 61482-1-2: 

This  personal  protective  garment  is  in  compliance  with  standard  EN  61482-1-2,  APC  1.  It  should  minimise  the  negative  effects  of  the 
exposure to arc flash. 

 

Use: 

Mainly in petrochemical industry, energetics, gas industry, refineries and ADR. As well as in flammable or explosive atmospheres (caused by 
incendiary discharge). The garment is also suitable for welding and other related processes. 
 

Caution: 

To  ensure  the  greatest  possible  protection  and  maintain  its  protective  properties,  the  personal  protective  garment  must  be  worn  in 

compliance with the manufacturer´s instructions, must be always well

-fastened (all zippers and Velcro closures) and complete. 

 

 

 

Reviews: