background image

V121203

AR-321H

EXIT

1
2
3
4
5
6
7
8

EXIT

1
2
3
4
5
6
7
8

E

N.C.

COM

PB

12V

GND

12V

GND

Exit Switch

12V

GND

12V

GND

12V

GND

12V

GND

12V

GND

N.O.

GND

N.O.

GND

N.O.

COM

PB

12V

GND

P1

P1

EXIT

1
2
3
4
5
6
7
8

N.C.
N.O.

COM

CTL

12V

1
2
3
4
5
6
7
8

Door Contact

ALM

12V

GND

12V

GND

12V

GND

12V

GND

12V

GND

12V

GND

12V

GND

N.O.

GND

N.C.

N.C.

N.O.

COM

PB

12V

GND

P1

P1

N.C.
N.O.
COM

CTL

12V

E

BZ

RLED
GLED

WG 0
WG 1

12V

GND

1
2
3
4
5
6
7
8

1
2
3
4
5
6

EXIT

12V
GND
Exit Switch

12V

GND

P2

P1

BZ
RLED
GLED
Door Output
WG 0
WG 1
DS
PB

7
8

1
2
3
4
5
6

P2

BZ
RLED
GLED
Door Output
WG 0
WG 1
DS
PB

7
8

EXIT

1
2
3
4
5
6
7
8

1   2   3

N.C.
N.O.

COM

CTL
12V

GND

PB

12V

GND

12V
GND

N.O.

12V

GND

12V

GND

DDR

P1

P6

ACC-899

4

12V

   

P1

PB                   

(BZ IN)

    

PB                   

(RLED IN)

SENSOR         

(GLED IN)

DURESS         

(WG 0 OUT)

ARMING OUT 

(WG 1 OUT)

P2

P2

P6

P6

WGoutput

Master

Fingerprint & Finger Vein

Biometrics Device Access controller 

Connect to Electric Bolt

Connect to Magnet Lock 

Wiring Diagram

Electric Bolt

Controller 

Controller 

Controller 

Controller 

Reader

Controller 

Controller 

RTE

RTE

RTE

RTE

RTE

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

Magnet Lock

Connect to Electric Strike

Electric Strike

Alarm

Relay Outpot Module 

Door Contact

Door Contact

Connect to Door Contact

Strengthen security with ACC-899

Electric Bolt

Connect to Reader

Notice

The communication wires and power line should NOT be bound in the same conduit or tubing.

Don’t equip controller and lock with the same power supply. The power for controller may be unstable when the lock is activating, that may make 
the controller malfunction.
The standard installation: Door relay and lock use the same power supply, and controller use independent power supply.

Use AWG 22-24 Shielded Twist Pair to avoid star wiring.

1.Tubing:
2.Wire selection:
3.Power supply:

ECL-ACC997 / ECL-ACC999 become WG mode

            (28   

 

016   )

1. When ECL-ACC997 / ECL-ACC999 become WG mode,it can be used 

     with any controllers.
2. ECL-ACC997 / ECL-ACC999 support Anti-pass-back by finger or card.

Using Rule : 

Finger : Both Master mode and WG mode device must store all the same FP data and

              real or virtual card number.  
Card : Can pass WG message to controller.

Summary of Contents for ECL-ACC997

Page 1: ...ED Output 5V 20mA Max 3 Brown Green LED Output 5V 20mA Max Door Output 4 Blue White Transistor Output Max 12V 100mA Open Collector Active Low Wiegand 5 Thin Green Wiegand DAT 0 Input 6 Thin Blue Wiega...

Page 2: ...ontroller RTE RTE RTE RTE RTE POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC Magnet Lock Connect to Ele...

Page 3: ...C997 ACL ACC999 set to exit reader WG Reader set to access reader Access programming mode 20 0 128 20 1 192 Please refer to function default value for details Enable Disable auto open zone Access prog...

Page 4: ...digit arming code Enable particular device Induct valid card Input 4 digit arming code U or Disable particular device Induct valid card Input 4 digit arming code U or Input 5 digit user address Input...

Page 5: ...n where finger can easily be placed 2 Use the middle or ring finger of either hand for the registration authentication purpose 3 Put your finger tip first to the top of the unit and lower the finger d...

Page 6: ...sticker on Ethernet Module device Please revise IP address you want and then click Update button After updating the IP please re connect the Web Browser by new IP address User Password The password c...

Page 7: ...r code settings 09 PPPPPPRRRRRR PPPPPP New master code RRRRRR Repeat the new master code Suspend or delete tags Suspend 10 SSSSS EEEEE Suspend Delete SSSSS starting user address EEEEE ending user addr...

Page 8: ...99 En Disable Skip Finger Tag 40 F NNNNN EEEEE First 40 1 NNNNN EEEEE Then 40 3 NNNNN EEEEE Function Default Value 20 U DDD Default Value Function Option Value Application Time Attendance 0 Yes 1 No 0...