10
4.2.2
VIDEO DISTRIBUTION QUICK START
To begin a video transmission
,
a matching between an encoder and a decoder is required
.
Each VEO-XTI1CG2 transmitter can stream a video signal over the network using an ID
channel number that must be unique in the same network. Each ID channel from 0 to 762
identifies a multicast address and every VEO-XRI1CG2 receiver can select one of these
channels in order to receive an AV stream.
The ID channel for transmitters is usually set once during the setting up of the system while
the receivers ID usually are the ones that are modified in order to show different content on
the displays. The destination receiver ID must be set in the same channel as the transmitter
broadcasting the desired source audio and video content.
The
ID channel can be selected in four different ways
:
•
By front panel buttons of the devices.
•
By using the Web Page configuration.
•
Via RS-232.
•
Via TCP using the VEO-XCTRLG2 controller.
4.2.3
UNICAST MODE
When VEO-XTI1CG2 and VEO-XRI1CG2 devices are
connected as a simple point to point
extension, no additional configuration is needed
.
1.
Connect the source device
to the VEO-XTI1CG2 transmitter to the HDMI port.
2.
Connect Audio IN/OUT
to a sound device and select the required audio mode.
3.
Connect the remote endpoint
to the VEO-
XRI1CG2 receiver’s HDMI port output.
4.
Connect the transmitter and receiver
with Cat5e/6/7 cable.
5.
Connect an RS-232 cable
from the automation system to the transmitter port.
6.
Connect RS-232 cable
from the receiver to the port of the device to control.
7.
Power VEO-XTI1CG2 transmitter and VEO-XRI1CG2 receiver
with the included
power adapter.
Set the same ID for both devices
.