Testing

1. Functional test

    Connect the main power cord of the pump. Manually fill the tank with 

 

    water until the pump turns on.

2. To test the overflow alarm circuit (EE400 and EE300 only) 

    a) Kink the tube coming from the pump discharge so it cannot pump    

        out. 

    b) Pour water into the pump reservoir, filling it completely.

    c) As the water level nears the top of the unit, the alarm  

        contact (EE400, please see "Wiring", pos.2) should activate and  

        trigger the desired function (e.g. acoustic signal) 

    d) Un-kink the tube and allow the pump to empty the tank. As the  

        water level goes down the overflow alarm contact will be 

 

        deactivaed and the appliance will energise again  

        (or the alarm will reset).

Maintenance 

Warning! Before attempting any maintenance on the unit, 

disconnect the power cord from the power supply to avoid the risk 

of electrical shock. 

Attention: The overflow alarm circuit (EE400 and EE300 only) can 

still be under power. 

If the pump does not perform as stated in above tests, remove the tank 

cover of the pump (EE400 only). The drive unit can be removed and 

cleaned now. The EE150 and EE300 can be opened by inserting a 

screwdriver in one of the side slots of the tank and levering it away (do 

not over-stress the material). After that, unscrew the two Phillips screws 

located on top (EE150 only). Now check the condition of surfaces which 

are in contact with the medium and/ or moving components. The tank, 

pump and the floats should be cleaned with mild detergent using a damp 

cloth. Please ensure that the tank and float mechanism are cleaned 

annually.

The motor itself does not need any maintenance so do not attempt any 

repairs. Also, never open the drive unit of the EE400 because breaking 

the seal will invalidate the warranty. Reassemble the pump in reverse 

order.  

Cleaning the check valve and verify its operating 

1. After unscrewing the cap nut remove the discharge line from the  

    check valve 

2. Use a SW 20 wrench to remove the check valve from the drive unit. 

3. Visually check the valve for obstructions. If damaged, replace. 

4. To re-install the check valve, hands tighten it to the drive unit.  

    Then, tighten 1/2-turn further with a wrench. 

Attention: Be careful not to over-tighten as this may distort the 

O-ring seal under the check valve. 

 

Replacement items

 

The discharge nipple with integrated check valve is available for 

replacement. (see table)

model

Item-number

description

EE150 / EE400

22214

check valve

EE300

22213

check valve

 

Troubleshooting 

If the pump does not function properly, refer to the following: 

1. Unit does not run: 

    a) Check the power supply 

    b) Check the appliance to see if condensation is actually being 

        generated 

    c) Check to make sure the pump float mechanism moves freely 

 

        (EE150, EE300) and whether the surfaces and/ or moving  

        components in contact with the medium are clean.  

        This applies in particular to the housing area underrneath the  

        cable entry, as the sensors are situated there inside the housing  

        (EE400).

    d) Check the drain line (s) into the pump for obstructions. Note: 

        If these lines are clogged and remain clogged, the appliance may   

        eventually be damaged. 

2. Pump makes loud noise when running: 

    a) Check the tank for debris and clean if necessary. Refer to the  

 

        maintenance section for cleaning instructions. 

3. Unit runs but does not pump liquid out:

    a) Check the height of the discharge tubing to be sure it does not  

        exceed the allowed head (see specifications)

    b) Check the discharge tube for obstructions and clear if needed.

    c) Check the check valve for obstructions. Refer to the maintenance  

        section for cleaning instructions. 

4. Liquid drains back into pump from discharge line: 

    a) Check valve may have debris in it. Refer to the maintenance  

        section for cleaning instructions 

    b) If the discharge line is plumbed so the highest point is less 

        than 1 m above the pump, the check valve may allow liquid to drain  

        out of the line. This is normal and will not damage the pump. 

5. Liquid leaks from around the check valve

 

    a) Check the proper fit of the cap nut that holds the discharge

        tube in place.

    b) If the check valve is too tight or too loose it may leak around

        the O-ring. Check that the valve is hand tight, and then tighten

        an addition 1/2 turn with a wrench. 

    c) If the O-ring under the check valve is damaged, replace with a    

        new one or purchase a replacement check valve, which includes an  

        O-ring.  

Warranty 

1 year. This warranty covers all parts with material or manufacturing 

faults. The buyer’s only remedy is the replacement or repair of the defec-

tive parts. In no case can labour costs and any consequential damage 

be cited as a basis for a complaint. Any returned units must be complete 

and must be accompanied by a written list of the defects ascertained. 

We are unable to accept any liability in case of nonconforming in-

stallation or noncompliance with the specifications or maintenance                 

recommendations.  

Conformity:

    

  

All data contained in these specifications are solely intended to describe 

the product and do not constitute warranted characteristics in the legal 

sense. 

Subject to technical modifications.

- 5 -

GB

Bedienungsanleitung EE400NEO-EE150-EE300_02_21.indd   5

08.02.2021   14:43:04

Summary of Contents for EE400

Page 1: ...sung Installation instructions Instruction d installation Istruzioni per l installazione Instrucciones bomba de condensados o EE300 EE150 EE400 Bedienungsanleitung EE400NEO EE150 EE300_02_21 indd 1 08...

Page 2: ...n die Pumpen vom Hersteller gr ndlich getestet bevor sie transportsicher verpackt wurden Falls M ngel auftreten oder gar erkennbar sind senden Sie die Pumpe zur Reparatur bzw Ersatzlieferung an Ihren...

Page 3: ...EE300 22213 R ckschlagventil St rungssuche Treten St rungen an der Pumpe auf beachten Sie folgende Hinweise 1 Pumpe l uft nicht a berpr fen Sie die Stromversorgung der Pumpe b Pr fen Sie ob Kondensat...

Page 4: ...arefully unpack the unit check for damage and make sure that all of the required parts are included The units are thoroughly tested before packing to insure safe delivery and operation If there is any...

Page 5: ...ump does not function properly refer to the following 1 Unit does not run a Check the power supply b Check the appliance to see if condensation is actually being generated c Check to make sure the pum...

Page 6: ...e de travail max 6 ON 5 OFF D bit th orique l h Hauteur de refoulement m max 120 0 max 80 1 0 1 5 Installation 1 Veuillez sortir la pompe de son emballage avec pr caution Effectuez un contr le visuel...

Page 7: ...erre trop fort Pi ces de rechange Comme pi ces de rechange pour les deux pompes nous pouvons vous livrer l embout de refoulement avec clapet antiretour int gr type de pompe Num ro de l article D signa...

Page 8: ...imballate per il trasporto le nostre pompe sono sottoposte a severe prove di funzionamento al fine di garantirne la sicurezza operativa Qualora costatiate eventuali difetti inviateci la pompa per rip...

Page 9: ...cate alcune cause di guasti e o anomalie che si pos sono presentare alla pompa ed i relativi rimedi 1 La pompa non funziona a Verificate che ci sia alimentazione elettrica b Controllate l unit verific...

Page 10: ...INSTALACION 1 Desembalar con mucho cuidado la bomba de condensados comprobar que no tiene ning n defecto y que contiene todos los elementos de la misma 2 Elegir un lugar para instalar la bomba que est...

Page 11: ...ambio Se puede utilizar tanto para la EE150 como para la EE400 modelo N mero de art culo Designaci n EE150 EE400 22214 la v lvula de retenci n EE300 22213 la v lvula de retenci n RESOLUCI N DE PROBLEM...

Page 12: ...x 100 3 0 4 EE300 230 50 65 230 3 NC NO 0 1600 1 0 200 110 145mm 8 2 10 o o o 100 p 2 5 6 ce 20 ce au a max 200 0 max 150 1 max 100 2 max 50 3 0 4 EE150 230 50 48 850 0 2 165 65 85mm 8 2 10 o o o 30 p...

Page 13: ...1 2 400 300 EE400 2 400 300 400 150 300 150 400 1 2 SW20 3 4 EE150 EE400 22214 EE300 22213 1 150 300 400 2 3 4 1 5 1 13 P Bedienungsanleitung EE400NEO EE150 EE300_02_21 indd 13 08 02 2021 14 43 04...

Page 14: ...Teoretyczna Wydajno t oczenia l h Wysoko t oczenia m maks 120 0 maks 80 1 0 1 5 Instalacja 1 Wyj pomp ostro nie z opakowania Sprawdzi czy urz dzenie nie posiada ewentualnych uszkodze oraz czy wszystk...

Page 15: ...rem zwrot nym model Numer artyku u oznaczenie EE150 EE400 22214 zaw r zwrotny EE300 22213 zaw r zwrotny Ustalanie uszkodze b dnego dzia ania W przypadku wyst powania b d w w dzia aniu nale y przestrze...

Page 16: ...9204 0 Fax 49 0 7246 9204 44 www eckerle com info eckerle com F r weitere Informationen besuchen Sie bitte unsere Internetseite unter For more informations visit our web site www eckerle com Stand 02...

Reviews: