Regulatory Statements

FCC Part 15.231 (315 and 902 MHz models only)

Contains FCC ID: TCM300C or TCM300U

The enclosed device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions: 

  (I.)  this device may not cause harmful interference and

  (ii.) this device must accept any interference received, including  

       interference that may cause undesired operation.

IC RSS-210: (315MHz and 902 MHz models only)

Summary of Contents for MOS-21 Series

Page 1: ...Motion Sensor with 868 MHz radio with high bay lens The package includes the occupancy sensor and installation guide MOS 21 Sensor Description The 21 series MOS sensor also referred to as the sensor...

Page 2: ...nds When the sensor awakens and no motion is detected the sensor transmits a vacancy telegram after 100 seconds 200 seconds total since the previous transmission The sensor will remain active until th...

Page 3: ...tly affect the receivers reception of the telegrams Before installing refer to the sections in the guide detailing the installation of wireless devices layout tips and test operation modes NOTE The se...

Page 4: ...the lens pops free 4 Choose a mounting method The sensor can be mounted With the screws and anchors not provided to a wall board ceiling Use a pencil to mark the mounting base key hole locations and r...

Page 5: ...accordance to the light level it is detecting see table below Light Level Test Indication Blinks Lux Foot candles Time to Fully Charge Discharge Time 0 0 0 below operating level n a 1 20 40 2 4 operat...

Page 6: ...nds 2 A quick press and release of the button at this point will allow you to select between test modes Pressing and releasing the test button scrolls through the LED indicators When the red LED is bl...

Page 7: ...me wall Avoid locating transmitters and receivers where the telegrams must penetrate walls at acute angles This increases the material the telegram must pass through reducing the signal power Avoid la...

Page 8: ...t notice Document 8DC 5492 Revision 1 4 8188M21 5492 1 Rev C Regulatory Statements FCC Part 15 231 315 and 902 MHz models only Contains FCC ID TCM300C or TCM300U The enclosed device complies with Part...