Echoflex Installation Guide

Open Loop CCT Sensor

Compliance

For complete regulatory compliance information, see the Open Loop CCT
Sensor datasheet at

echoflexsolutions.com

.

FCC Compliance

Echoflex Open Loop CCT Sensor
(For any FCC matters):
Echoflex Solutions, Inc.
3031 Pleasant View Road
Middleton, WI 53562
+1 (608) 831-4116

echoflexsolutions.com

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received; including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. Any modifications or changes to this product not expressly approved by
Electronic Theatre Controls, Inc. could void the user’s authority to operate the product.
Operation of this equipment in a residential area is likely to cause harmful interference, in
which case the user will be required to correct the interference at their own expense.

Contains FCC ID: TCM300U

ISED Compliance

This device contains a license-exempt transmitter/receiver that complies with Innovation,
Science, and Economic Development Canada’s license-exempt RSSs. Operation is subject to
the following two conditions:

1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired

operation of the device.

Contains IC ID: 5713A-STM300U

Conformité ISDE

Cet appareil contient un émetteur/récepteur conforme aux CNR d'Innovation, Sciences et
Développement économique Canada (ISDE) applicables aux appareils radio exempt de licence.
Son fonctionnement est soumis aux deux conditions suivantes:

1. L'appareil ne doit pas produire d'interférences.
2. L'utilisateur de l'appareil doit accepter toute interférence, même si l'interférence est

susceptible d'en compromettre le fonctionnement.

Contient ID IC: 5713A-STM300U

Open Loop CCT Sensor

Page 8 of 8

Echoflex

Summary of Contents for FLS-41

Page 1: ...throughout the day The sensor can monitor exterior light levels up to 100 000 lux 9 290 fc and a color temperature range of 2 000 to 7 500 kelvin with a resolution of 10 and an accuracy of 100 kelvin This document covers installation testing and setup of all FLS 41 models The product package includes the sensor and incorporated adhesive pads for mounting Prepare for Installation To ensure optimal ...

Page 2: ... sensor right up against the window to ensure reflections from interior lights do not affect the sensor readings The location and position of the sensor directly affects the quality of messages received by the linked controller Note Consider linking the FLS 41 while you have access and before replacing the cover See Link to a Controller on the facing page Obstruction Obstruction 60 Field of view 6...

Page 3: ...nds Link to a Controller The compatible target controller must be installed powered and within range of the FLS 41 Note The linking process can be used both to link a device to a controller and to unlink a linked device from a controller 1 Press the Learn button on the controller to activate Link mode If necessary refer to the controller product documentation 2 Press the Teach button on the sensor...

Page 4: ...minutes 100 9 3 64 seconds 10 minutes 100 200 9 3 18 6 32 seconds 320 seconds 200 18 6 16 seconds 160 seconds For the sensor to send an on change message it needs sufficient power Stored energy above 3 5 V or Ambient light level above 300 lux 27 9 fc On Change Formula The sensor compares the current sample value to an average of the last three readings If the difference is more than 12 the sensor ...

Page 5: ...hold the Teach button until the green LED is displayed Release the button to enter the menu and display the first item the blinking green LED 2 Press and hold the Teach button again until the green LED stops blinking The green LED then repeats a number of blinks according to the detected light level The sensor reevaluates the light level every two seconds Blinks Ambient Light Lux Footcandles Time ...

Page 6: ...80 dBm good Red 80 to 95 dBm poor move closer No LED No linked controllers detected The test repeats every five seconds and runs for 50 seconds To exit before the time out press and hold the Teach button Rapid Response Test The Rapid Response Test confirms the settings on powered controllers to which the FLS 41 is linked The test accelerates the sensor s message rate making the controller respond ...

Page 7: ...ress and release the Teach button to cycle through the menu of color LEDs and stop when the blue and red LEDs are both blinking 3 Press and hold the Teach button until the LEDs stop blinking to select EEP Select The blue LED blink code displays the current setting 4 Press and release the Teach button to navigate the options Indication Setting 1 blue blink EEP A5 06 04 Curtain Wall Brightness Senso...

Page 8: ...s Any modifications or changes to this product not expressly approved by Electronic Theatre Controls Inc could void the user s authority to operate the product Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense Contains FCC ID TCM300U ISED Compliance This device contains ...

Reviews: