6. OPERATION
WARNING
• Never operate the engine in a closed area or it may cause
unconsciousness and death within a short time. Operate the engine in a
well ventilated area.
• Before starting the engine, do not connect any electric devices.
NOTICE
• The generator has been shipped without engine oil. Do not start the
engine till fill with the sufficient engine oil.
• Do not tilt the generator when adding engine oil. This could result in
overfilling and damage to the engine.
TIP:
The generator can be used with the rated output load at standard atmo-
spheric conditions.
“Standard atmospheric conditions”
Ambient temperature 25
Barometric pressure 100kPa
Relative humidity 30%
The output of the generator varies due to change temperature, altitude (lower
air pressure at higher altitude) and humidity.
The output of the generator is reduced when the temperature, the humidity
and the altitude are higher than standard atmospheric conditions.
Additionally, the load must be reduced when using in a confined area, as
generator cooling is affected.