background image

INSTALLATION INSTRUCTION - 

OPTIONS 

 

 

BOOST PUMP 

 

 
If the high-pressure pump is installed less than 1 foot below the waterline or an additional 5micron pre-
filter is added, the installation of an optional boost pump is recommended. 
 
Install the boost pump with the electric motor up or sideways in a dry location (submergible pumps are 
available)  below  the  water  line,  in  between  the  sea  strainer  and  the  pre-filter(s).    The  intake  is  at  the 
center of the pump.   
 
Be  sure  your  electrical  wiring  for  this  pump  switches  off  and  on  at  the  same  time  the  electric  high 
pressure pump motor switches off and on, to prevent the pump from being damaged.  
 
The ECHO Tec. “Orbital” Magnetic Drive Pumps eliminate the conventional shaft seals found in most 
pumps.  This means that there is no rotating seal to wear and allow the liquid being pumped to leak out. 
 
We  rely  on  the  liquid  being  pumped  to  lubricate  the  impeller-magnet  assembly  spinning  on  the 
stationary spindle. If the pump is run dry for longer than 10 minutes, the plastic may “freeze” onto the 
spindle. 
 
All pumps can be serviced with the use of a screwdriver.  The only moving part in the pump other than 
the  motor,  is  the  impeller-magnet  assembly.    This  assembly  rotates  on  a  stationary  spindle  and  up 
against a thrust washer.  These are the only parts that can wear and may need to be replaced. 

 

 

5 MICRON PRE-FILTER HOUSING  

 

 
Connect  the  filter  housing  with  the  supplied  ¾”  nylon  nipple  to  the  standard  filter  housing  and 
reconnect  the  reinforced vinyl  hose.    The  5micron  cartridge  has  to  be  installed  as the  second  filter  in 
flow direction.   

 

5 MICRON PRE FILTER HOUSING WITH LOW PRESSURE GAUGE 

 
The optional 5micron pre filter housing with low pressure gauge has to be installed as a second filter in 
flow direction. 

 

FRESHWATER FLUSH SYSTEM 

 

 

Install  the  active  carbon  filter  housing  at  a  serviceable  location  in  between  your  freshwater  system 
pump and the pre-filter housing(s).  Connect one port of the shut off valve to the provided barbed tee.  
Connect the two remaining ports of the tee to the outlet of the storage/cleaning valve and to the intake 
of  the  high  pressure  pump  (refer  to  the  flow  diagram).    Connect  the  intake of  the  active  carbon  filter 
housing to your boat’s pressurized water system. 
 
If  the  optional  3/4"  nylon  tee  with  cleaning/storage  valve  (systems  without  boost  pump)  is  supplied 
connect the outlet of the active carbon filter housing with the ½” barbed nipple of the 3 way valve.  The 
shut off valve of the flush filter housing should be re-located to the intake side. 

Summary of Contents for 200-AMS-1

Page 1: ...EM FEATURES OPTIONS AND ACCESSORIES 6 FLOW DIAGRAM 7 9 INSTALLATION INSTRUCTIONS 10 INSTALLATION INSTRUCTIONS OPTIONS 11 12 SYSTEM OPERATION SHUT DOWN AND FLUSH PROCEDURE 13 MEMBRANE CLEANING PROCEDUR...

Page 2: ...st products on the market The purpose of this manual is to allow you to become familiar with each component of your new ECH2O Tec Watermaker By understanding the function importance and normal operati...

Page 3: ...ce is tested at 26 C 80 F water temperature and 33g NaCl ltr RO MEMBRANE TYPE Specifically selected high rejection proprietary TFC Polyamid thin film composite spiral wound single pass reverse osmosis...

Page 4: ...uct flow meter 25 50 100gph 1 Diverter 3 way valve 1 Breaker 20amp 230V or 30amp 115V or 2 Breakers like above and 5 amp with optional boost pump 6 15 feet 4 5 meter high pressure hose with 2 x 316 hi...

Page 5: ...al cartridge 316 bracket 8 screws shut off valve 2 x 5 8 hose barb connectors 10ft 1 2 braided hose 4 x 1 2 hose clamps Low pressure gauge The low pressure gauge indicates when the pre filters have to...

Page 6: ...ermakers DATE 31 05 06 REV 3 1 DRWN MS BOOST PUMP FRESH WATER FLUSH FILTER FILTER STRAINER FILTER PUMP FILTER 5 20 PSI PSI FLOW REJECT WATER REJECT WATER OUTLET CLEANING STORAGE SOLUTION INTAKE R O ME...

Page 7: ...all other components and hoses tubes are completely assembled remove the caps on the high pressure fittings and the blue sealed tube from the product water outlet on the membrane housing s and then f...

Page 8: ...a 20foot length so it may be cut to suit your needs Leave a little extra length of hose Never bend the high pressure hose tighter than a 4 10cm radius Assembly instructions for the 316 stainless steel...

Page 9: ...ted water to back flow from your water tanks into the R O membrane and does not require a new fitting in your tank When using a spigot as the taste test station be sure you have no shut off valves in...

Page 10: ...impeller magnet assembly This assembly rotates on a stationary spindle and up against a thrust washer These are the only parts that can wear and may need to be replaced 5 MICRON PRE FILTER HOUSING Co...

Page 11: ...er valve to sample position 5 Switch on the boost pump optional 6 Switch on the high pressure pump 7 Flush the air out of the system Check the brine discharge at the output location Caution Never allo...

Page 12: ...If you intend to store your watermaker for more than seven days growth of micro organism will degrade the RO membrane s performance The RO membrane s should be flushed with a biocide solution This wi...

Page 13: ...Do not use different cleaning chemicals together at the same time Mix the cleaning chemicals separately and use them separately Note All cleaning and preserving procedures can be done with either sea...

Page 14: ...trainer Inspect and clean screen and housing 100 hrs or when clogged Pre filters s Replace element s and clean housing s 200 hrs or when clogged suction higher than 3 Hg Carbon flush filter Replace el...

Page 15: ...gear box oil non detergent Check inlet lines for restrictions and or proper size Check strainer and filter s Inability to build up pressure Discharge valve chamber has air trapped within it Allow mor...

Page 16: ...16B and copper gasket 16D and clean the old Locktite from the plunger bolt 16C and plunger base 16A Replace the plunger with the new one and Locktite the plunger bolt and torque to 120 inch pounds NOT...

Page 17: ...s 12A and 12B if they were removed from the crankshaft Be certain the bearings are pressed all the way onto the shaft and completely into the crankcase Replace radial shaft seal 11 bearing cover with...

Page 18: ......

Page 19: ...s Service Center The purchaser must pay any transportation or labor expenses incurred in removing and returning the product to the service center The limited warranty does not extend to any system com...

Page 20: ...lete with Reverse Osmosis Membrane Element s However if the ECHO Tec System will not be put to use within 9 months of shipment there is a potential danger of the Reverse Osmosis Membrane Element s fou...

Reviews: