13.
CONFEO PREMIX P COMPONENT DEFINITIONS
•
Siphon
Subject
Description
Part’s Function
The component that allows the discharge of condensing water and rainwater
without allowing the discharge of waste gas.
Impact in Case of
Malfunction
1-
Water rises in the siphon due to siphon clogging.
2-
The siphon discharges waste gas to the external environment.
Main Associated Error
Codes
E01
Error Diagnostics-Test
Method and Maintenance
Visually inspect that there is no dirt, burrs, etc. in the siphon and the siphon
is clean.
Siphon cleaning steps:
1- Move the siphon upwards.
2- Turn it counterclockwise.
3-
Move downwards using a hand tool or by hand.
4-
Remove the filth accumulated in the siphon by washing.
5-
If there is filth in the condensing water hose, clean it as well.
1
2
3
4
5
Table
9
60
Summary of Contents for CONFEO PREMIX P 14 HM
Page 1: ...SERVICE MANUAL CONFEO PREMIX CONDENSING BOILER CONFEO PREMIX P 14 20 24 28 30 35 HM HCH HST...
Page 24: ...12 ELECTRICAL DIAGRAM Figure 15 24...
Page 34: ...Low Voltage Removing installing the pump cable FAN PWM CABLE Figure 39 Figure 40 34...
Page 52: ...Figure 76 Figure 77 52...
Page 83: ......