P44:
This is the parameter used to set the off temperature of the domestic water when it is active.
P45:
This is the parameter used to activate the room thermostat.
Def
a
ult
value is "1=active".
P46:
This is the parameter used to set the time for the display light to go off if no button is pressed on
the device.
P47:
This parameter used to activate the buzzer has 4 options.
0. Not active (all sounds off)
1. Active (all sounds on)
2. Error sounds not active (button sounds are active, but error sounds are not active)
3. Button not active (button sounds are not active, but error sounds are active)
P48:
This is the language selection parameter which you can set to English or Turkish. When the pa
-
rameter adjusted to English language ,
Service Phone Number feature
opens.
P49:
This is the parameter used to activate predictive maintenance warnings (risk of flame loss, risk of
high water pressure, risk of low water pressure).
P50:
This parameter enables the domestic water delay to be activated for the time specified against
the instantaneous high pressure risk that may occur in the installation. This value should be increased
in installations where there is high water-hammer effect.
Service Phone Number:
You can save the number of authorized service in your country with this
parameter.
When the device gives an error or a warning, the authorized service number that you
entered from the service number parameter appears at the bottom of the LCD screen.
5
.
ENTERING THE INQURY MENU
The Inqury Menu gives information about the device during operation. It allows the user to view real
time data on the menu screen. When you are in the menu, you can see the real time values of the de
-
vice by using the DHW +/- buttons no 2 and 4.
1. Supply Water Temperature between 00 and 125 °C
2. Return Water Temperature between 00 and 125 °C
3. DHW Temperature between 00 and 125 °C
4. DHW Sen. Tank Below 00 and 125 °C
5. Solar Temperature between 00 and 125 °C
6. Exhaust Gas Temperature between 00 and 125 °C
7. Exterior Temperature
8. Current Fan Speed
9. Current Water Pressure
10. Ionization current 00 to 99 uA
11. Firmware Version C_x.xx
Figure 6
11
Summary of Contents for CONFEO PREMIX P 14 HM
Page 1: ...SERVICE MANUAL CONFEO PREMIX CONDENSING BOILER CONFEO PREMIX P 14 20 24 28 30 35 HM HCH HST...
Page 24: ...12 ELECTRICAL DIAGRAM Figure 15 24...
Page 34: ...Low Voltage Removing installing the pump cable FAN PWM CABLE Figure 39 Figure 40 34...
Page 52: ...Figure 76 Figure 77 52...
Page 83: ......