background image

1 1

P

P

P

P

P

P

P

P

1

N

0 3

2

N

0 3

P

P

P

P

9. HOLD Command

The user can send SMS command and overtake control of a relay and keep it active (ON) until cancelation command is
received for each one of the two relays.
When the relay is in HOLD mode, it will not function to any other command until a cancelation command is received.
Instead of activating the relay, the unit will send SMS to the user that says “

Hold Command is Active

”  

if the user

tried to open the gate with his mobile phone.
=> The user can send SMS of HOLD COMMAND to overtake control of any one of the two relays as follows:

To send HOLD command by SMS    

To Cancel the HOLD command by SMS 

PPPP represent the 4 digit PASWORD.   
The letter “ N ” represents relay 1 or relay 2. 

Example of SMS HOLD command for relay 2:     9999**03*21# 
The unit will send SMS to the sender to confirm Hold Command as follows: “

Confirming Relay 2 is Active ON

” 

 Example of SMS canceling HOLD command for relay 2:      9999**03*22# 
SMS confirming t of cancelling Hold Command will be received as follows: “

Confirming Relay 2 is no longer Hold Active

” 

 

You can send one SMS to cancel both Hold commands for both the relays as follows: 

999**03*12#,**03*22# 

 

You can send one SMS to cancel both Hold commands for both the relays as follows: 

9999**03*12#,**03*22# 

10. How to limit the Talking Time

You can select and limit the talking time with the visitor by SMS command.
The factory default limit time is 59 second (before the next flag fall).
The system will end up each call (after the chosen “Talking Time”) by an announcement: “ 

END OF CALL

” .

To change the talking time by SMS command, send the SMS as follows:

The letters “ PPPP ” represent the 4 digit PASWORD.   
The letters “T  T “  represent the time in seconds according to the table below: 
Enter:  0   0   => for Zero talking time 

 ; 

Enter:  3   0   => for 30 seconds talking time 

 ; 
 ; 

 Enter:  5   9   => for 59 seconds talking time 

(Default) 

 Enter:  6   1   => for 1 Minute talking time 

  

 Enter:  6   2   => for 2 Minutes talking time 

  

 Enter:  6   3   => for 3 Minutes talking time 

  

 ; 
 ; 

 Enter:  6   9   => for 9 Minutes talking time 
 Enter:  7   0   => for 10 Minutes talking time 

  

 Enter:  9   9   => for unlimited talking time. (Not recommended). 
The unit will confirm by sending SMS message to the sender as follows: “

Confirming the talking time was changed

 “ 

11. How to check the next available empty memory cell in the system

In order to get the next available empty memory position in the system by SMS command, send SMS as follows:

PPPP 

represent the 4 digit PASWORD.   

The unit will send SMS reply to the sender that says:

 “ The nest available position is X X X “    

The letters X X X represent three digit number (such as 055) to indicate the empty memory position. 

Summary of Contents for COMMUNICATOR GSM18V82

Page 1: ...the gate If the person that called was not one of the authorized users it will just hang up and do nothing 4 The SIM CARD You would need a MINI size SIM card to be used with this unit Insert the SIM...

Page 2: ...Door Station Model DS 12 The push button is not supplied with the unit and can be ordered separately Optional Relay 2 Com Relay 1 N O 12V 24V Ac Dc Min 2Amp Power Supply EXIT Push Button Relay 1 Com...

Page 3: ...following example is to add the first three phone numbers and delete the fourth one 9999A001 0395720535 A002 0395720555 A003 0395720535 D004 The system will confirm by SMS message to the sender as fo...

Page 4: ...command sent followed by the word CONFIRMED or FAILED at the end of the message How to Cancel or Activate the SMS service in the unit You can Cancel or Activate the SMS service of the unit by sending...

Page 5: ...et the Relays PULSE time interval For each one of the relays 1 or 2 you can choose the time interval of the pulse for the momentary function The factory default setting for both the relays is a 4 seco...

Page 6: ...th Hold commands for both the relays as follows 9999 03 12 03 22 10 How to limit the Talking Time You can select and limit the talking time with the visitor by SMS command The factory default limit ti...

Page 7: ...he PASSWORD The factory default password is 9999 You can change the password by sending the following SMS message The letters P P P P represent the old password The letters W W W W represent the new p...

Reviews: