1. Programming the phone numbers into the system.

The first three phone numbers in the system are the numbers which the unit will dial when the Call Button No 1 is pressed and the
next 4

th

, 5

th

 and 6

th

 phone numbers in the memory are for Call Button No. 2. These phone numbers are the first six users of the

GSM access control that are able to open the gate with their mobile phones with no cost of a call.
All the programming and settings of this unit can be done by using any mobile phone to send SMS messages with the following
commands.

ADDING USER’S PHONE NUMBERS BY SMS COMMAND

Use the following format of SMS message to add or change user’s phone numbers in the system:

-

The first four letters represent the 

P

assword ( P P P P )

.The factory default Password is 9 9 9 9

-

Followed by the letter “ A ” that represents 

A

dding (or changing) the user’s phone number.

-

Then 

( U U U ) represent the user’s memory location number, 

from 001 to 999

 followed by the star ( 

*

 )symbol.

-

And then (

N N N  ….  N N N

) represent the phone number followed by the 

hash 

#

 ) 

symbol. 

          

 

Please note! 
You can send one SMS message with multiple (more than one) command to add or delete users as the 
following format.  

=> The following example is to add the first three phone numbers and delete the fourth one: 

 9999A001*0395720535#,A002*0395720555#,A003*0395720535#,D004# 

=> The system will confirm by SMS message to the sender as follows: 

 A001*0395720535#,A002*0395720555#,A003*0395720535#,D004#CONFIRMED 

2. Deleting users’ phone numbers in the system.

You can program a new phone number instead of an old one, by simply programming a new phone number for the
same memory location. The system will automatically delete the old number and replace it with the new user’s phone
number for the same memory location.

 

Deleting the users’ phone numbers by SMS command. 

Use the following format of SMS message to delete user’s phone numbers in the system: 

-

The first four letters represent the 

P

assword ( P P P P ). 

The factory default Password is 9 9 9 9

-

Followed by the letter “ D ” that represents 

D

eleting a user phone number.

-

Then 

( U U U ) represent the user’s memory location number, 

from 001 to 999

 followed by the hash (#) symbol.

Example of SMS message programming the first user’s phone number which is 0395720535 

9999A001*0395720535# 

Please Note: 

The system is sensitive to 

cases

 

and 

space

 between the letters.

  

The system will confirm the SMS command by sending SMS message to the sender to confirm. 

U

U

U

N

N

N

N

N

N

.

.

.

P

P

P

P

A

Example of SMS message DELETING the first phone number in the memory which is 0395720535 

9999D001# 

=> Please Note: 

The system is sensitive to 

cases

 

and 

space

 between the letters.

  

 

Summary of Contents for COMMUNICATOR GSM18V82

Page 1: ...the gate If the person that called was not one of the authorized users it will just hang up and do nothing 4 The SIM CARD You would need a MINI size SIM card to be used with this unit Insert the SIM...

Page 2: ...Door Station Model DS 12 The push button is not supplied with the unit and can be ordered separately Optional Relay 2 Com Relay 1 N O 12V 24V Ac Dc Min 2Amp Power Supply EXIT Push Button Relay 1 Com...

Page 3: ...following example is to add the first three phone numbers and delete the fourth one 9999A001 0395720535 A002 0395720555 A003 0395720535 D004 The system will confirm by SMS message to the sender as fo...

Page 4: ...command sent followed by the word CONFIRMED or FAILED at the end of the message How to Cancel or Activate the SMS service in the unit You can Cancel or Activate the SMS service of the unit by sending...

Page 5: ...et the Relays PULSE time interval For each one of the relays 1 or 2 you can choose the time interval of the pulse for the momentary function The factory default setting for both the relays is a 4 seco...

Page 6: ...th Hold commands for both the relays as follows 9999 03 12 03 22 10 How to limit the Talking Time You can select and limit the talking time with the visitor by SMS command The factory default limit ti...

Page 7: ...he PASSWORD The factory default password is 9999 You can change the password by sending the following SMS message The letters P P P P represent the old password The letters W W W W represent the new p...

Reviews: