40
|
Diagnostics
40
User Manual
Phase
The current phase value (same as Phase option described later in this section).
Solv Add
When Press (Set Pressure) exceeds this value, solvent will be automatically added by the printer (same
as Solvent Add on the PRESSURE REFS screen).
Ref VOD
The reference VOD as input with the printhead code.
Ref MOD
The reference modulation determined by the last printhead calibration or set by the user (same as Ref
Modulation in the SETUP menu).
Read Press
The current read pressure being measured by the pressure transducer. This will normally be the same
as Press (Set Pressure), accurate to +14 bits.and -14 bits.
Your local EC-JET distributor may ask you to read-off the values shown against some of the above
parameters to help diagnose any problems you may have.
System Times (System Timing Information)
The SYSTEM TIMES menu shows statistical information on the number of hours the power has been
on and the jet has been running, the filter life expired and the time due until service.
The menu is called up from the DIAGNOSTICS menu:
Power On
Number of hours power has been on.
Jet Running
Number of hours the jet has been running.
Filter Change
Recommended hours left until a main ink filter change is required. Starts at 2000 and counts down by
the number of hours the jet has been running.
Service
Recommended hours left until service required. Starts at 2000 and counts down by the number of hours
the jet has been running.
System Config (System Configuration Information)
It is useful to know at a glance what versions of software or data PROMS are fitted, what raster type
is being used and which type of printhead is fitted to the printer.
All this information is shown in the SYSTEM CONFIGURATION menu which is displayed by selecting
the System Config option from the DIAGNOSTICS menu:
DIAGNOSTICS
VOD
PRESSURE
PHASE
00000
000
Jet Off
2006-03-24 14:01:38
Flush Shutdown
Monitor Jet
> System Times
System Config
EJ84
SYSTEM TIMES
VOD PRESSURE PHASE
00000
000
Jet Off
2006-03-24 14:01:38
> Power On
Jet Running
Filter Change
Service