Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-Z8910SP User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
7
to resume sleep.
When data needs to be received, the data is received through periodic wake-up. The longer the wake-up period is set, the
longer the reception will be. The wake-up period setting must be less than 30 seconds. If you only need to upload data,
you can set the wake-up period to be greater than 30 seconds or longer to reduce power consumption (the default is 10
seconds), such as battery-powered sensors.
1.4 Application scenarios
Smart home and industrial sensors, etc.;
Security system, positioning system;
Wireless remote control, UAV;
Wireless game remote control;
Medical and healthcare products;
Wireless voice, wireless headset;
Advanced meter reading architecture (AMI);
Applications in the automotive industry;
Building automation solutions;
Application of agricultural greenhouse automation;
2. Technical Parameters
2.1 Limit parameter
Main parameter
Performance
Note
Min
Max
Voltage supply [V]
1.9
3.6
Voltage over 3.6V will cause permanent damage to
module
Blocking power [dBm]
-
10
Chances of burn is slim when modules are used in
short distance
Operating temperature [
℃
]
-40
+85
Industrial grade
2.2 Operating parameter
Main parameter
Performance
Note
Min
Typ
Max
Voltage supply [V]
1.9
3.3
3.6
≥3.3 V ensures output power