DATA: actual parameters
FF: end of command
Configuration Return:
FC CMD STATUS
FC: fixed head
CMD: Actual named ID
STATUS: 00 operation is successful
01 operation failed
6.4.2 Read instruction set
Instruction description
Comma
nd ID
Instruction format
Command example
Read device type
01
Send:
FE 01 01 FF
Return:
FB 01 dev_type
Send:
FE 01 01 FF
Return:
FB 01 03
Read network status
02
Send:
FE 01 02 FF
Return:
FB 02 nwk_state
Send:
FE 01 02 FF
Return:
FB 02 02
Read network PAN_ID
03
Send:
FE 02 03 FF
Return:
FB 03 pan_id
Send:
FE 02 03 FF
Return:
FB 03 FE 5B
Read local network
short address
05
Send:
FE 02 05 FF
Return:
FB 05 Short_Addr
Send:
FE 02 05 FF
Return:
FB 05 F6 FA
Read local MAC
address
06
Send:
FE 08 06 FF
Return:
FB 06 Mac_Addr
Send:
FE 08 06 FF
Return:
FB 06 1F 1C 21
FE FF 57 B4 14
Read the short network
address of the parent
node
07
Send:
FE 02 07 FF
Return:
FB 07 Coor_shortAddr
Send:
FE 02 07 FF
Return:
FB 07 00 00
Read the MAC address
of the parent node
08
Send:
FE 08 08 FF
Return:
FB 08 Coor_Mac_Addr
Send:
FE 08 08 FF
Return:
FB 08 0C 46 0C
FE FF 9F FD 90
Read network group
number
09
Send:
FE 01 09 FF
Return:
FB 09 group
Send:
FE 01 09 FF
Return:
FB 09 01
Read communication
channel
0A
Send:
FE 01 0A FF
Return:
FB 0A channel
Send:
FE 01 0A FF
Return:
FB 0A 0B
Read transmit power
0B
Send:
FE 01 0B FF
Return:
FB 0B txpower
Send:
FE 01 0B FF
Return:
FB 0B 0A