Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-Z8910SP User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
25
6.5.2 Receive data output mode
Read command format:
Command format
Command example
Send: FE 01 26 FF
Return: FB 27 out_mode
Send: FE 01 27 FF
Return: FB 27 00
Configuration instruction format:
Command format
Command example
Send: FD 01 27 mode FF
Return: FA 27
Send: FD 01 27 00 FF
Return: FA 26
mode:
0x00 transparent transmission (default);
0x01 data + short address;
0x03 data+RSSI;
0x04 data + short a RSSI;
Note: The sender supports a single packet with a maximum data packet length of 82 bytes
6.5.3 Network node type
Read command format:
Command format
Command example
Send: FE 01 01 FF
Return: FB 01 dev_type
Send:
FE 01 01 FF
Return:
FB 01 03
Configuration instruction format:
Command format
Command example
Send: FD 01 01 dev_type FF
Return: FA 01
Send: FD 01 01 03 FF
Return: FA 01
dev_type:
0x03 terminal (default)
0x04 Sleep terminal
The configuration of changing the node type needs to be restarted to take effect. In normal operation, the device
configured with the node type will leave the current network in a non-network state, and will switch to the changed node
type after restarting. The dormant terminal supports the wake-up function of the serial port receiving pin. The first frame
of data sent by the serial port during sleep is the wake-up frame. It is recommended to use the 5-byte "FF" to wake up
"FF FF FF FF FF".