Chengdu Ebyte Electronic Technology Co,;Ltd E32-DTU (433NW20) user manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co,;Ltd 15
111
:
2000ms
---------------------------------------------
2. FEC switch
0: close the FEC
1: turn on FEC (default)
---------------------------------------------
1, 0 Transmission power (approximate)
00
:
20dBm
(
Default
)
01
:
17dBm
10
:
14dBm
11
:
11dBm
-------------------------------------
After FEC is turned off, the
actual data transmission rate
will be increased, but the
anti-interference ability will be
weakened and the distance
will be slightly closer. Please
select according to the actual
application.
Both sides of the
communication must be on or
off.
-------------------------------------
External power supply must
provide more than 500mA
current output capacity. And
ensure that the power ripple is
less than 100mV.
It is not recommended to use a
small power transmission; its
power utilization efficiency is
not high.
For example: The meaning of No.3 "S PED" byte:
The binary bit of the
byte
7
6
5
4
3
2
1
0
Configures by user
0
0
0
1
1
0
0
1
M eaning
UART parity bit 8N1
UART baud rate is 9600
Air data rate is 2k
Corresponding
hexadecimal
1
9
Summary of Contents for E32-DTU
Page 1: ...E32 DTU 433NW20 ...