8.2. Parameter setting instruction
Parameter
Description
Baud rate
The serial port baud rate of a wireless data station at work
,
1200bps
~
115200bps
。
Odd-even check
Support 8N1:no check
;
8E1:even-check
;
8O1:odd-check
;
Both are 8-bit data bits and 1-bit stop bits.
Air data rate
(
bps
)
Wireless communication rate, also known as air baud rate air rate high, data transmission speed,
transmission of the same data time delay is small, but the transmission distance will become shorter.
Transmitting power
In order to ensure the working efficiency, it is recommended to use the maximum power. If the
transmitted power is reduced, the communication distance will become shorter and the required current
will be reduced
FEC
The lost or interfered data can be partially corrected by complex encoding, which can improve the
equivalent receiving sensitivity by about 3dBm. Turning off this function can reduce the
communication delay.
Transmission mode
Transparent transmission, and send-as-received fixed points: data is sent at fixed points according to
the format
Wake Up Time
There is no direct relationship with the communication delay. If the customer needs low-power
applications, this option shall be adjusted as required. In the power-saving mode, the longer the
wake-up time, the lower the power consumption of the receiving end, and the greater the
communication delay.