Chengdu Ebyte Electronic Technology Co., Ltd
E32-433T30D User Manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
14
7.4 Reset command
Instruction format
Description
C4+C4+C4
In sleep mode
(
M0=1
,
M1=1
)
,
User gives the module instruction (HEX format): C4 C4 C4, the module resets for one time.
During the reset process, the module will conduct self-check, AUX outputs low level. After
reset completing, the AUX outputs high level, then the module starts to work regularly which
the working mode can be switched or be given another instruction.
7.5 Parameter setting command
Item
Description
Remark
0
HEAD
Fix 0xC0 or 0xC2, it means this frame data is control
command
Must be 0xC0 or 0xC2
C0: Save the parameters when power-down
C2: Do not save the parameters when
power-down
1
ADDH
High address byte of module
(
the default 00H
)
00H-FFH
2
ADDL
Low address byte of module
(
the default 00H
)
00H-FFH
3
SPED
7
6
UART parity bit
UART mode can be different between
communication parties
0
0
8N1 (default)
0
1
8O1
1
0
8 E1
1
1
8N1 (equal to 00)
5
4
3
TTL UART baud rate
(
bps
)
UART baud rate can be different
between communication parties
The UART baud rate has nothing to do
with wireless transmission parameters
& won’t affect the wireless transmit /
receive features.
0
0
0
1200
0
0
1
2400
0
1
0
4800
0
1
1
9600 (default)
1
0
0
19200
1
0
1
38400
1
1
0
57600
1
1
1
115200
2
1
0
Air data rate
(
bps
)
The lower the air data rate, the longer
the transmitting distance, better
anti-interference
performance
and
longer transmitting time
The air data rate must keep the same
for both communication parties
0
0
0
0.3k
0
0
1
1.2k
0
1
0
2.4k
(
default
)
0
1
1
4.8k
1
0
0
9.6k
1
0
1
19.2k
1
1
0
19.2k
(
same to 101
)
1
1
1
19.2k
(
same to 101
)
4
CHAN