same time the work load and power consumption of the whole system have been reduced and the efficiency of
whole system is largely improved.
6.2 Normal mode (mode 0)
When M1 = 0 & M0 = 0, module works in mode 0
Transmitting
The module can receive the user data via serial port, and transmit wireless data package of 58
bytes. When the data inputted by user is up to 58 byte, the module will start wireless
transmission. During which the user can input data continuously for transmission.
When the required transmission bytes are less than 58 bytes, the module will wait 3-byte time
and treat it as data termination unless continuous data inputted by user. Then the module will
transmit all the data through wireless channel.
When the module receives the first data packet from user, the AUX outputs low level.
After all the data are transmitted into RF chip and transmission start , AUX outputs high level.
At this time, it means that the last wireless data package transmission is started, which enables
the user to input another 512 bytes continuously. The data package transmitted from the
module working in mode 0 can only be received by the module working in mode 0 or 1.
Receiving
The wireless receiving function of the module is on, the data packet transmitted from the
module working in mode 0 & mode 1 can be received.
After the data packet is received, the AUX outputs low level, 5ms later the module starts to
transmit wireless data through serial port TXD pin.
After all the wireless data have been transmitted via serial port, the AUX outputs high level.
6.3 Wake-up mode (mode 1)
When M1 = 0 & M0 = 1, module works in mode 1
Transmitting
The condition of data packet transmission & AUX function is the same as mode 0. The only
difference is that the module will add preamble code before each data packet automatically.
The preamble code length depends on the wake-up time set in the user parameters. The
purpose of the preamble code is waking up the receiving module works in mode 2. Therefore,
the data package transmitted from mode 1 can be received by mode 0, mode1 and mode 2.
Receiving
The same as that in mode 0.
6.4 Power-saving mode (mode 2)
When M1 = 1 & M0 = 0, module works in mode 2
Transmitting
UART is closed, the module cannot receive any serial port data from outside MCU.
Hence the function of wireless transmission is not available for the module working in this
mode.
Receiving
In mode 2, it is required the data transmitter works in mode 1.
The wireless module monitors the preamble code at regular time.
Once it gets the preamble code, it will remain as receiving status and waiting for the
completion of receiving the entire valid data package.
Then the AUX outputs low level, 5ms later the serial port is open to transmit received wireless
data through TXD. Finally, AUX outputs high level after process completed.
The wireless module stays in “power-saving – monitoring” working status (polling).
By setting different wake-up time, the module will have different receiving response delay (2s