1. Forwarding rules, the relay can forward data in both directions between two NETIDs.
2. In the relay mode, ADDH\ADDL is no longer used as a radio address, but as a NETID forwarding pairing.
As shown in the figure:
①
First level relay
"Node 1" NETID is 08.
"Node 2" NETID is 33.
The ADDH\ADDL of relay 1 are 08 and 33 respectively.
So the signal sent by node 1 (08) can be forwarded to node 2 (33)
At the same time, node 1 and node 2 have the same address, so the data sent by node 1 can be received by node 2.
②
Secondary relay
The ADDH\ADDL of relay 2 are 33 and 05 respectively.
So relay 2 can forward the data of relay 1 to the network NETID: 05.
Therefore, node 3 and node 4 can receive node 1 data. Node 4 normally outputs data, and node 3 has a different address
from node 1, so no data is output.
③
Two-way relay
As shown in the configuration: the data sent by node 1 can be received by nodes 2 and 4, and the data sent by nodes 2
and 4 can also be received by node
9 Relay Networking Mode Use
The following figure shows the display interface of the E96-DTU (400SL30-485) configuration host computer. The
user can switch to the configuration mode through the MODE button, and quickly configure and read the
parameters on the host computer.